LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2019 >> Sprinter 3500XD 2D Cab Chassis >> Repair and Diagnosis >> Accessories & Equipment >> Wiper/Washer Systems >> Electrical System, Equipment & Instructions - Battery, Forms, Wiring Diagrams & Special Tools >> Update Software Of Instrument Cluster >> Update Software Of Instrument Cluster (Code: Vs3ORTUNKI, Acc. No.: 54 903 74) - SM54.30-D-0041SG

Update Software Of Instrument Cluster (Code: Vs3ORTUNKI, Acc. No.: 54 903 74) - SM54.30-D-0041SG

Model 907 with code JH3 (Communication module (LTE) for digital services) 

Operation no. of the operation texts or standard texts and flat rates
Category Op. no. Operation text Time Acc. no. Code
L 02 2443 Operations: Connect/disconnect vehicle diagnosis system - 54 903 74 VS3ORTUNKI
L 02 2445 Operations: Connect/disconnect charger (vehicle diagnosis system connected) - 54 903 74 VS3ORTUNKI
L 02 2442 Operations: Update control unit software (vehicle diagnosis system connected) - 54 903 74 VS3ORTUNKI
  Notes on programming control units   AH54.21-P-0001-03Z
INSPECT Check     
1 Check whether vehicle is affected by measure. Affected vehicles: Update software of instrument cluster (code: VS3ORTUNKI, acc. no.: 54 903 74)
Model 907.### ## as of 000185 to 232380
SM54.30-D-0041-01AAA
    IMPORTANT For authorized Mercedes-Benz service partners, only the entry in the Extended VEGA Application (EVA) system, in the "Current" tab is decisive. An additional test of the affected vehicles in the workshop information system (WIS) or vehicle list is thereby not necessary.  
  Update software     
2 Connect diagnostic system.    
REFER TO SELF-DIAGNOSTIC SYSTEMS     AD00.00-D-2000-06TS
    IMPORTANT Always use the latest XENTRY Diagnosis software release.
IMPORTANT It is absolutely essential to precisely follow the operation steps as described in the vehicle diagnosis system.
 
3 Connect charging equipment.    
REFER TO TESTING & REPAIR Maintaining on-board electrical system voltage when performing test and diagnosis work on vehicle   AR54.10-D-1127TS
    NOTES
During the entire work procedure a sufficiently large voltage supply must be provided for the vehicle's on-board electrical system.
Otherwise any undervoltage that occurs may damage the control units.
IMPORTANT Follow the operating instructions for the charger.
IMPORTANT Use the charger to ensure that an adequate power supply (min. 12.5 V) is provided for the on-board electrical system battery.
 
4 Update instrument cluster (IC) software. IMPORTANT It is absolutely essential to precisely follow the operation steps as described in the vehicle diagnosis system.  
5 Disconnect diagnostic system.    
REFER TO SELF-DIAGNOSTIC SYSTEMS     AD00.00-D-2000-06TS
6 Remove charger from vehicle.    
REFER TO TESTING & REPAIR     AR54.10-D-1127TS