Connect/Disconnect Testing Unit At Brake Booster - AR43.10-P-0024-01GZ
Model 164, 166, 292
Show on model 164.1
Connecting
- Operate brake pedal several times.
In order to reduce the vacuum in the BAS brake booster (A7/7).
- Disconnect vacuum line with check valve (2) from BAS brake booster (A7/7).
Mount test connection (3) between BAS brake booster (A7/7) and vacuum line with check valve (2).
Pay attention to manufacturer's operating instructions.
Otherwise measurement errors can occur.
Connect vacuum tester (1) to
test connection (3).
Disconnect
- Disconnect in reverse order.