Air Conditioning - BE83.30-P-1000-04A
WARNING: This page is about a different car, the 2023 Mercedes-Benz GLC300, 2022 Mercedes-Benz GLC300, 2021 Mercedes-Benz GLC300, 2020 Mercedes-Benz GLC350e, and 2020 Mercedes-Benz GLC300. However, it is still accessible from the selected car via links, so may be relevant.
Model 118, 164, 166, 167, 169, 171, 177, 190, 197, 199, 204, 205, 206, 207, 209, 211, 212, 213, 216, 217, 218, 219, 221, 222, 223, 230, 232, 238, 240, 243, 245, 247, 251, 253, 257, 290, 292, 293, 297, 463
AIR CONDITIONING
| Number | Designation | Model 118, 164, 166 167, 169, 171, 177, 190, 197, 199, 204, 205, 206, 207, 209, 211, 212, 216, 218, 219, 221, 230, 238, 240, 243, 245, 247, 251, 253, 257, 290, 292, 293 Model 213, 217, 222 except code 1U6 (R744 refrigerant) | Model 213, 217, 222 with code 1U6 (R744 refrigerant) | ||
|---|---|---|---|---|---|
| BE83.30-P-1001-04A | Pressure drop in refrigerant circuit filled with test gas | Test pressure | bar | 15 | 90 |
| Test period | h | 4 | 4 | ||
| Permissible fluctuation of ambient temperature | °C | ±2 | ±2 | ||
| Pressure drop | bar | 0 | <1 | ||
| BE83.30-P-1002-04A | Preliminary test for pressure drop test | Test pressure | bar | - | 50 |
| Test period | min | - | 1 | ||
| Pressure drop | bar | - | 0 | ||
AIR CONDITIONING
| Number | Designation | Model 232 | Model 463 as of model year 2019 | ||
|---|---|---|---|---|---|
| BE83.30-P-1001-04A | Pressure drop in refrigerant circuit filled with test gas | Test pressure | bar | 15 | 15 |
| Test period | h | 4 | 4 | ||
| Permissible fluctuation of ambient temperature | °C | ±2 | ±2 | ||
| Pressure drop | bar | 0 | 0 | ||
| BE83.30-P-1002-04A | Preliminary test for pressure drop test | Test pressure | bar | - | - |
| Test period | min | - | - | ||
| Pressure drop | bar | - | - | ||
AIR CONDITIONING
| Number | Designation | Model 223, 297 | ||
|---|---|---|---|---|
| BE83.30-P-1001-04A | Pressure drop in refrigerant circuit filled with test gas | Test pressure | bar | 15 |
| Test period | h | 4 | ||
| Permissible fluctuation of ambient temperature | °C | ±2 | ||
| Pressure drop | bar | 0 | ||
| BE83.30-P-1002-04A | Preliminary test for pressure drop test | Test pressure | bar | - |
| Test period | min | - | ||
| Pressure drop | bar | - | ||