Remove/Install Communications Module/Stationary Heater Antenna - AR82.62-P-0002LW
Model 205.0/1/3
with code 350 (Ecall emergency call system, Europe)
Model 205.0/3
with code B24 (Remote control for Auxiliary heating)
Model 205.0/3
with code B54 (Live Traffic Information)
Fig 1: Communications Module/Stationary Heater Antenna Components Location - Model 205.0/3 With Codes 350, B24 And B54
| Information on preventing damage to electronic components due to electrostatic discharge | AH54.00-P-0001-01A | ||
| Remove/install | |||
| 1 | Remove rear shelf | Model 205.0/1 with code 350 (Ecall emergency call system, Europe) Model 205.0 with code B24 (Remote control for Auxiliary heating) Model 205.0 with code B54 (Live Traffic Information) |
AR68.30-P-4581LW |
| Model 205.3 with code 350 (Ecall emergency call system, Europe) Model 205.3 with code B24 (Remote control for Auxiliary heating) Model 205.3 with code B54 (Live Traffic Information) |
AR68.30-P-4581CLW | ||
| 2 | Lift foam material (1) in center | ||
| 3 | Disconnect electrical connector (2) | ||
| 4 | Lift safety spring (3) and pull communications module/stationary heater antenna (A2/129) forward as far as it will go (arrow A) | ||
| 5 | Turn communications module/stationary heater antenna (A2/129) by 90° counterclockwise (arrow B) and remove | ||
| 6 | Install in the reverse order |