Retrofit Illuminated Door Sill Molding Wiring Harness - AZ82.20-P-0001-04GQ
MODEL 166.0/8
- Disconnect yellow plug B (1) from rear control unit (N10/8).
- Remove contact carrier for pin 1 to 26 from yellow connector B (1).
- Plug line from left illuminated door sill molding wiring harness (2) into contact cavity 12 of contact carrier.
- Plug line from right illuminated door sill molding wiring harness (3) into contact cavity 11 of contact carrier.
- Reinstall contact carrier in yellow plug B (1) and connect to rear control unit (N10/8).
- Connect ground cable (7) from illuminated door sill molding wiring harness to ground point (W17):
- Route left illuminated door sill molding wiring harness (2) under left cable duct (4) and foam material (5) to left front footwell.
- Clip black, 2-pin connector (6) from left illuminated door sill molding wiring harness (2) into cable duct.
- Route right illuminated door sill molding wiring harness (3) under right cable duct (8) and foam material (9) to right front footwell.
- Clip black, 2-pin connector (10) from right illuminated door sill molding wiring (3) into wiring harness.
- Program interior lighting package.