Remove/Install Air Body Control Central Reservoir - AR32.22-P-2023LWX
Model 253.364/388/389/964/988/989 with code 489 (AIR BODY CONTROL)
| Note on calculation of tightening torque when using insertion or socket tools with various effective lengths | AH00.00-P-0015-01CW | ||
| Notes on AIRMATIC | AH32.22-P-1000-02LW | ||
| Remove | |||
| 1 | Drain AIR BODY CONTROL central reservoir (1) using vehicle diagnosis system | ||
| AD00.00-P-2000-04B | |||
| 2 | Fold over load compartment floor rear section | ||
| 3 | Switch off ignition and store transmitter key outside of transmitter range (at least 2 m) | ||
| 4 | Remove hazard warning triangle | ||
| 5 | Remove pressure line (2) from AIR BODY CONTROL central reservoir (1) and close off openings with suitable stop plugs | Fig 4 | |
| Fig 3 | |||
| 6 | Remove bolt (3) and open tensioning strap (4) | ||
| 7 | Remove AIR BODY CONTROL central reservoir (1) upwards out of the trunk | ||
| Install | |||
| 8 | Position AIR BODY CONTROL central reservoir (1) in trunk | ||
| 9 | Close tensioning strap (4) and tighten bolt (3) | ||
| 10 | Remove all stop plugs | ||
| 11 | Attach pressure line (2) to AIR BODY CONTROL central reservoir (1) | Otherwise, leaks will occur. |
|
| *BA32.22-P-1007-03G | |||
| Fig 4 | |||
If thread on the pressure line (2) or pressure line (2) connection is damaged ↓ Repair connection of pressure line (2) or pressure line (2). |
Fig 1 | ||
| AR32.22-P-2001-01LW | |||
| Fig 2 | |||
| 12 | Position warning triangle in trunk | ||
| 13 | Fill AIR BODY CONTROL central reservoir (1) with compressed air using vehicle diagnosis system | ||
| AD00.00-P-2000-04B | |||
| Check | |||
| 14 | Read out and erase fault memory using the diagnostic system | ||
| AD00.00-P-2000-04B | |||
| 15 | Check AIR BODY CONTROL central reservoir (1), pressure line (2) and connection of pressure line (2) for leak tightness | AR32.22-P-8100LW | |
| Install | |||
| 16 | Fold back load compartment floor rear section |
AIR SUSPENSION
| Number | Designation | Model 253 | |
|---|---|---|---|
| BA32.22-P-1007-03G | Pressure line to pressure reservoir/valve unit (SP) | Nm | 3, 5 |