LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2018 >> GLC300 Base >> Repair and Diagnosis >> Electrical >> Motors, Switches, Relays >> Electrical System, Equipment & Instruments - 253 Chassis - 4 Of 7 >> Testing & Repair >> Emergency Release Of Charging Cable Plug At Charger Feed Socket - AR54.10-P-5111LVH

Emergency Release Of Charging Cable Plug At Charger Feed Socket - AR54.10-P-5111LVH

Model 253.311/353/354/911/953/954 

G12938371Courtesy of MERCEDES-BENZ USA

Shown on model 253.954 

  Risk of death  when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. AS00.00-Z-0035-01A
  General information on handling vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system   AH00.00-Z-0300-01A
  Notes on battery   AH54.10-P-0001-01A
  Notes on safety-relevant components   AH00.00-Z-0019-01A
  Emergency release     
1 Unlock vehicle and open trunk lid.    
2 Unclip cover (1).    
3 Pull plug emergency release (2) in direction of arrow using extraction hook and disconnect charging cable connector from charger feed-in socket. IMPORTANT Before pulling the plug emergency release (2), make sure that the electrical charging at the charging station/infrastructure has been completed.
IMPORTANT By pulling the plug emergency release (2), the turntable platform of the mechanical emergency release on the actuator motor of the electrical release is twisted and the charging cable connector is released.
 
    SPECIAL TOOL Extraction hook Fig 1
4 Attach cover (1).    
5 Close charger feed-in socket flap.    
6 Close socket flap in rear bumper.    
Fig 1: Identifying Extraction Hook (140 589 02 33 00)
G11129281Courtesy of MERCEDES-BENZ USA