Remove/Install COMAND APS Hard Disk - AR82.85-P-1001GW
Model 463
as of model year 2013 up to model year 2019
| Remove/install | |||
| Information on preventing damage to electronic components due to electrostatic discharge | AH54.00-P-0001-01A | ||
| 1 | Perform commissioning of hard drive (2) on COMAND controller unit (A40/3) using STAR DIAGNOSIS | ||
| Connect STAR DIAGNOSIS and read out fault memory | AD00.00-P-2000-04A | ||
| 2 | Remove COMAND controller unit (A40/3) | Remove/install COMAND controller unit | AR82.85-P-1100GW |
| 3 | Place COMAND controller unit (A40/3) on an Electrostatic Discharge (ESD) work station | Make sure that the COMAND controller unit (A40/3) is placed on an Electrostatic Discharge (ESD) work station. Otherwise, damage can occur to the electronics of the COMAND controller unit (A40/3) or hard drive (2). |
|
| 4 | Remove bolt (1) | ||
| 5 | Remove hard drive (2) upwards (arrow) | Avoid touching the conductor tracks on the printed circuit board. Otherwise, damage can occur to the electronics of the hard drive (2) or COMAND controller unit (A40/3). |
|
| 6 | Install in the reverse order | ||
| 7 | Perform function test | ||