LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2017 >> SL65 AMG >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Electrical System, Equipment & Instruments - 231 Chassis >> Testing & Repair >> Check condition of additional battery - AR54.10-P-1128RK

Check condition of additional battery - AR54.10-P-1128RK

Model 231 with CODE B03 (ECO start/stop function) 

Fig 1: Screw, Bracket, Ground Cable, Positive Line, Retaining Tabs, Cover, Frame And Eco Start/Stop Function Additional Battery
G11128938Courtesy of MERCEDES-BENZ USA
DANGER Risk of explosion  from explosive gas. Risk of poisoning and caustic burns  from swallowing battery electrolyte. Risk of injury  through burns to skin and eyes from battery acid or when handling damaged lead-acid batteries No fires, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses.
Only pour battery acid into suitable and appropriately marked containers.
AS54.10-Z-0001-01A
NOTES Notes on battery   AH54.10-P-0001-01A
IMPORTANT Notes on AGM battery   AH54.10-P-0002-01A
REMOVING Remove     
1 Remove right side paneling in rear   AR68.30-P-4780RK
2 Switch off ignition and remove transmitter key (A8/1) or KEYLESS-GO start/stop button (S2/3) from electronic ignition lock control unit (N73) IMPORTANT KEYLESS-GO start/stop button (S2/3) only with code (889) KEYLESS-GO.  
3 Remove frame (9) at stowage compartment IMPORTANT To do so, unclip the frame (9), swing upward at the front and remove the frame (9) toward the front.  
4 Unscrew bolts (1) and remove bracket (2)    
5 Release retaining tabs (7) and fold up cover (8) in direction of arrow    
INSPECT Check     
6 Visually inspect additional battery for ECO start/stop function (G1/13) for signs of external leaks In event of leakage to additional battery for ECO start/stop function (G1/13).

Replace additional battery for ECO start/stop function (G1/13).
Remove/install additional battery
AR54.10-P-0007RK 
7 Check additional battery for ECO start/stop function (G1/13) Check battery AR54.10-P-1129-01A
REFER TO SPECIAL TOOLS 000 588 02 19 00 Battery tester   WS54.00-N-3006B 
    Battery capacity 12 Ah *BE54.10-P-1001-01A 
8 Charge and check additional battery for ECO start/stop function (G1/13) If "Change and check" is shown in the display of the Midtronics battery tester and test equipment.
IMPORTANT Charge additional battery for ECO start/stop function (G1/13) directly at the battery terminals and check again after charging.
 
INSTALLING Install     
9 Install in the reverse order    
TEST AND ADJUSTMENT VALUES FOR BATTERY

Number Designation Model all
BE54.10-P-1001-01A Battery capacity 12 Ah Cold cranking amps As per EN A 170