(Exhaust Treatment Function - GF14.00-P-3000OGR)
ENGINE 642.8 in MODEL 166 up to model year 2016
Function requirements for exhaust treatment, general points
- Circuit 87M (engine management ON)
- Engine runs
Exhaust treatment, general
The task of exhaust treatment is to reduce the exhaust emissions:
- Nitrogen oxides (NOx)
- Hydrocarbons (HC)
- Carbon monoxide (CO)
- Soot particles
Pollutant reduction is supported by the following subfunctions:
- Intake port shutoff (EKAS)
- Diesel particulate filter (DPF) preheating (with code 474 (Particulate filter))
- Exhaust gas recirculation (EGR)
- Injection of the reduction agent AdBlue® (with code U42 (BLUETEC (SCR) diesel exhaust treatment))
The CDI control unit (N3/9) reads in the following signals:
- Temperature sensor upstream of SCR catalytic converter (B16/15) (with code U42 (BlueTEC (SCR) diesel exhaust treatment))
- Temperature sensor upstream of catalytic converter (B19/7) (with code U42 (BlueTEC (SCR) diesel exhaust treatment))
- Temperature sensor upstream of diesel particulate filter (B19/9) (with code 474 (Particulate filter))
- Temperature sensor upstream of ATL (B19/11)
- DPF differential pressure sensor (B28/8) (with code 474 (Particulate filter))
- Oxygen sensor upstream of catalytic converter (G3/2)
- SAM control unit (N10), outside temperature via the body CAN (CAN B), electronic ignition lock control unit (N73) and chassis CAN 1 (CAN E1)
- NOx sensor control unit downstream of diesel particulate filter (N37/7), signal for NOx sensor downstream of diesel particulate filter (N37/7b1) via drive train sensor CAN (CAN I) (with code U42 (BlueTEC (SCR) diesel exhaust treatment)
- NOx sensor control unit downstream of SCR catalytic converter (N37/8) (with code U42 (BlueTEC (SCR) diesel exhaust treatment), signal from NOx sensor downstream of SCR catalytic converter (N37/8b1) via the drive train sensor CAN (CAN I)
- Soot particulate sensor control unit (N74) with soot particulate sensor (N74b1) (from AJ12 with code U42 (BlueTEC (SCR) diesel exhaust treatment)) and code 494 (USA version)) via the drive train sensor CAN
Function sequence for exhaust treatment
The following subsystems are involved in exhaust treatment:
- Function sequence for diesel oxidation catalytic converter
- Function sequence for diesel particulate filter (DPF)
- Function sequence for SCR catalytic converter (with code U42 (BLUETEC (SCR) diesel exhaust treatment))
- Function sequence for intake port shutoff
Function sequence for diesel oxidation catalytic converter
The diesel oxidation catalytic converter ensures lowering of hydrocarbon (HC), carbon monoxide (CO) and nitrogen oxides (NOx) and generates the required thermal energy for the DPF regeneration phase for vehicles with code 474 (Particulate filter) through afterburning.
Function sequence for diesel particulate filter (DPF)
The diesel particulate filter consists of a ceramic honeycomb filter body made out of silicon carbide, which is coated with rare metal platinum. The passages of the diesel particulate filter are opened alternately at the front and rear and are separated from each other through the porous filter walls of the honeycomb filter body.
The exhaust precleaned by passing through the diesel oxidation catalytic converter flows into the ducts of the DPF which are open to the front and passes through the porous filter walls of the honeycomb filter body into the ducts which are open to the rear. After this, the cleaned and filtered exhaust is dissipated through the exhaust system. The soot particles are retained in the honeycomb filter body of the DPF. If the soot particle content exceeds a map-based value, the CDI control unit will start the regeneration phase provided the prerequisites for regeneration are given. The CDI control unit receives the information on soot particle content in the DPF via the DPF differential pressure sensor ().
Regeneration takes place by means of a periodical increase of the exhaust temperature. For this purpose, the following functions are initiated by the CDI control unit:
- One additional post injection via the fuel injectors (Y76)
- DPF glow function over the drive train LIN (LIN C1) over the glow output stage (N14/3) to the glow plugs (R9)
- - Switching line shift via the drive train CAN (CAN C) by the fully integrated transmission control controller unit (Y3/8)
The soot particles retained in the DPF are mostly burnt off to produce carbon dioxide (CO2) by increasing the exhaust temperature. The ash produced remains in the DPF. For vehicles with code 474 (Particulate filter), the exhaust temperature is monitored during regeneration by the temperature sensor upstream of the ATL and by the temperature sensor upstream of the diesel particulate filter.
Through the exhaust pressure lines upstream and downstream of the DPF, the DPF differential pressure sensor determines the pressure differential between the exhaust gas pressure upstream and downstream of the DPF. The soot particle content in the DPF is determined using a characteristics map on the basis of the pressure differential and the exhaust mass calculated by the CDI control unit. Necessary maintenance of the DPF is signaled via chassis CAN 1, the electronic ignition lock control unit and chassis CAN 2 (CAN E2) by the engine diagnosis indicator lamp (A1e58) in IC (A1).
On short-distance trips, regeneration is interrupted and distributed over several driving cycles. This means that more heating-up phases up to the required regeneration temperature will occur. Regeneration occurs unnoticeably by the customer.
From AJ12 (for vehicles with code U42 (BlueTEC (SCR) diesel exhaust treatment) and code 494 (USA version)), the soot particulate concentration in the exhaust is also determined by the soot particulate sensor and sent to the soot particulate sensor control unit. The CDI control unit receives the signal about the soot particulate contents from the soot particulate sensor control unit.
Function sequence for SCR catalytic converter (with code U42 (BLUETEC (SCR) diesel exhaust treatment))
The exhaust expelled from the engine is cleaned in a diesel oxidation catalytic converter, a diesel particulate filter (DPF) and an SCR catalytic converter (selective catalytic reduction).
Oxidation in the diesel oxidation catalytic converter chemically converts CO and HC to CO2 and water (H2 O). The diesel particulate filter consists of a ceramic honeycomb filter body made out of silicon carbide, which is coated with rare metal platinum.
The passages of the diesel particulate filter are opened alternately at the front and rear and are separated from each other through the porous filter walls of the honeycomb filter body.
The exhaust precleaned by passing through the diesel oxidation catalytic converter flows into the ducts of the DPF which are open to the front and passes through the porous filter walls of the honeycomb filter body into the ducts which are open to the rear. The soot particles are retained in the honeycomb filter body of the DPF. During the DPF regeneration phase, the higher exhaust temperature burns off the retained soot particles.
The AdBlue® reduction agent is injected upstream of the SCR catalytic converter and is converted to ammonia (NH3) through thermal decomposition (heat-induced chemical reaction) and hydrolysis (water-induced chemical reaction).
There is a mixing element between the AdBlue® metering valve (Y129) and the SCR catalytic converter. This improves the hydrolysis of the AdBlue® reduction agent and ensures more uniform distribution of the AdBlue® upstream of the SCR catalytic converter.
In the SCR catalytic converter, the NOx contained in the exhaust is converted together with the NH3 to molecular nitrogen (N2 ) and H2 O.
The CDI control unit calculates the quantity of reduction agent required based on a characteristics map and sends it via drive train sensor CAN to the AdBlue® control unit (N118/5). This control unit then initiates map-based injection of the calculated quantity of AdBlue® reducing agent through the AdBlue® metering valve.
The conversion rate of the NOx portion in the exhaust is dependent on the temperature and can be up 80%. Soot portion is reduced by approx. 99%.
The CDI control unit determines the load condition of the DPF over the DPF differential pressure sensor and DPF differential pressure sensor for OBD. If the soot content exceeds a characteristics map-based value, the CDI control unit will start the regeneration phase provided the prerequisites for regeneration are given. Regeneration is performed by periodically raising the exhaust temperature with another post injection.
Raising the exhaust temperature causes most of the soot particles stored in the DPF to be burnt off to CO2 .
The noncombustible ash remains in the DPF. During regeneration, the exhaust temperature is monitored by the temperature sensor upstream of the ATL and by the temperature sensor upstream of the diesel particulate filter. Necessary maintenance of the DPF is signaled by the engine diagnosis indicator lamp in the instrument cluster.
If the "Reserve" fill level in the AdBlue® container is reached, the driver is informed by an acoustic signal and by a "Service Required" message on the multifunction display (A1p13), in which case the driver should contact the workshop to obtain the appropriate maintenance.
If the fill level "empty" is reached in the AdBlue® container, the plausibility of the "empty" fill level is checked through a computer model. If the plausibility check also results in an "empty" fill level, an acoustic signal is given in parallel, an entry is made in the fault memory of the control unit (CDI), and the engine diagnosis indicator lamp is actuated on the instrument cluster.
The driver then has up to 20 engine starts available, with an assumed trip distance of 32 kilometers in each case. The number of standing starts is displayed in the instrument cluster. The vehicle can no longer be started after the last remaining "Start".
Function sequence for intake port shutoff
The intake port shutoff (EKAS) achieves the best possible relation between eddy and air mass in all load conditions of the engine.
For intake port shutoff the CDI control unit also reads in the following signals:
- Engine oil temperature sensor (B1)
- Atmospheric pressure sensor, for the atmospheric pressure
- Accelerator pedal sensor (B37), for load detection
- Crankshaft Hall sensor (B70), for engine speed
After evaluating the input signals, the CDI control unit actuates the intake port shutoff actuator motor (M55) by means of a pulse width modulated (PWM) signal. In the lower engine speed and engine load range, half of the intake ports (2 intake ports per cylinder available) are closed by means of the intake port shutoff flaps. In the open intake ports, the flow rate is thus increased. This leads to a higher swirl which creates a better vortex. This improves combustion and also contributes to reducing the soot particles in the exhaust gas.
As engine speed and load increases, the closed intake ports open continuously, so that the best possible relation between air eddying and air mass is provided for each operating phase of the engine. In this way, the exhaust characteristics and the engine performance are optimized.
If there is a fault or discontinuity in the supply voltage, the flaps are opened by spring force.
| Electrical function schematic for exhaust treatment | PE14.00-P-2051-97NAC | ||
| Overview of system components for common rail diesel injection (CDI) | GF07.16-P-9997OGR |