Remove/Install Electric Refrigerant Compressor - AR83.55-P-5311GQA
MODEL 166.063
MODIFICATION NOTES
| 06.10.2016 | Compressor oil specification changed | Operation step 15 | BB00.40-P-0362-01A |
| 06.10.2016 | Safety note added | AS83.00-Z-0006-01A | |
| 06.10.2016 | Safety note added | AS83.00-Z-0007-01A | |
| 06.10.2016 | Safety note added | AS00.00-Z-0010-01A | |
| 06.10.2016 | General note added | AH83.30-N-0003-01A | |
| 06.10.2016 | General note added | AH83.30-P-0003-02A |
| Risk of poisoning caused by inhaling overheated refrigerant vapors from an air conditioning system containing R134a. Risk of injury to skin and eyes caused by contact with liquid R134a refrigerant and when working on pressurized parts | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. Model 166.063 except code 2U8 (Alternative refrigerant) | AS83.00-Z-0006-01A | |
| Risk of fire due to ignition of R1234yf refrigerant on hot components. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with escaped R1234yf refrigerant and when working on pressurized parts. Risk of explosion due to formation of ignitable refrigerant/air mixtures | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. Model 166.063 with code 2U8 (Alternative refrigerant) | AS83.00-Z-0007-01A | |
| Risk of death when touching components on vehicles with high-voltage on-board electrical system | Do not touch damaged or defective components and open lines of the high-voltage on-board electrical system. Persons who wear electronic implants (e.g. cardiac pacemakers), must not carry out any work on high-voltage on-board electrical systems. | AS54.00-Z-0001-01A | |
| Risk of death caused by vehicle slipping or toppling off of the lifting platform. | Align vehicle between vehicle lift columns and position the four support plates at the vehicle lift support points specified by the vehicle manufacturer. | AS00.00-Z-0010-01A | |
| Note on high-voltage on-board electrical system | AH54.00-P-0010-01A | ||
| Evaluation of high-voltage components | AH54.00-P-6500-01SXH | ||
| Information on preventing damage to electronic components due to electrostatic discharge | AH54.00-P-0001-01A | ||
| Notes on handling refrigerant R134a | Model 166.063 except code 2U8 (Alternative refrigerant) |
AH83.30-N-0003-01A | |
| Notes on handling refrigerant R1234yf | Model 166.063 with code 2U8 (Alternative refrigerant) |
AH83.30-P-0003-02A | |
| Remove/install | |||
| 1 | Drain air conditioning system | AR83.30-P-1760CW | |
| 2 | Perform disable for the high-voltage on-board electrical system | AR54.10-P-1150GQA | |
| 3 | Switch off ignition and store transmitter key outside of transmission range (min. 2 m) | ||
| 4 | Remove top engine cover | ||
| 5 | Remove left air intake duct | ||
| 6 | Remove electrical vacuum pump | AR43.05-P-0001GQA | |
| 7 | Remove front and center underfloor paneling | AR61.30-P-1001GQ | |
| 8 | Remove left charge air pipe | Model 166.063 with engine 276.8 | AR09.41-P-8620GQC |
| 9 | Slacken poly-V-belt and lock tensioning device | Model 166.063 with engine 276.8 | AR13.22-P-1202GQC |
| 10 | Unclip electrical sub wiring harness (2) from vacuum pump bracket (1) | Fig 2 | |
| 11 | Remove screws/bolts (3) and remove vacuum pump bracket (1) | *BA43.05-P-1006-01K | |
| 12 | Release and disconnect high voltage plug (5) from electrical refrigerant compressor (4) | ||
| 13 | Protect high voltage plug (5) of electrical refrigerant compressor (4) against moisture | Fig 1 | |
| 14 | Remove screws/bolts (6) of the refrigerant lines (8) | *BA83.55-P-1003-01M | |
| 15 |
Remove refrigerant lines (8) and place to one side Compressor oils (specification 362.1) |
BB00.40-P-0362-01A | |
| 16 | Seal refrigerant lines (8) and openings in electrical refrigerant compressor (4) using suitable stop plugs | The refrigerant line (8) openings and electric refrigerant compressor (4) openings must be closed off. Otherwise penetrating dirt and moisture will damage the components that are connected to the refrigerant circuit. |
Figure |
| 17 | Remove bolt (7) from the electric refrigerant compressor (4) | *BA83.55-P-1001-01M | |
| 18 | Release and disconnect electrical connector (9) from electric refrigerant compressor (4) | ||
| 19 | Remove screws/bolts (10, 11) on electric refrigerant compressor (4) and remove electric refrigerant compressor (4) downwards | *BA83.55-P-1001-01M | |
| 20 | Install in the reverse order | ||
| Check | |||
| 21 | Evacuate the air conditioning system, refill it, and then check the system to make sure that it functions correctly and does not leak | AR83.30-P-1760CW |
VACUUM PUMP
| Number | Designation | Engine 276 in model 166, 222 | |
|---|---|---|---|
| BA43.05-P-1006-01K | Screw/bolt, bracket for electrical vacuum pump to timing case/crankcase | Nm | 35 |
REFRIGERANT COMPRESSOR
| Number | Designation | Engine 276 | |
|---|---|---|---|
| BA83.55-P-1001-01M | Screw/bolt, refrigerant compressor to timing case/crankcase/engine support | Nm | 20 |
REFRIGERANT COMPRESSOR
| Number | Designation | Engine 276 | ||
|---|---|---|---|---|
| BA83.55-P-1003-01M | Bolt, refrigerant line to refrigerant compressor | M8 | Nm | 20 |