Correct oil level in air conditioning system when replacing AC compressor - AR83.55-P-5250GW
MODEL 463 as of model year 2013/model refinement package 2012
| Correct oil level | |||
| Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerants. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been emptied. | AS83.00-Z-0001-01A | |
| Procedure for a damaged or leaky air conditioning system | AH83.30-N-0004-01A | ||
| Protect air conditioning circuit and components from moisture when carrying out repair work | All models with air conditioning | AH83.30-N-0005-01A | |
| Notes on handling R134a refrigerant | Air conditioning with refrigerant R134a | AH83.30-N-0003-01A | |
| Repair work for defective refrigerant circuit | AH83.30-P-1782-01A | ||
| 1 | Drain new refrigerant compressor | ||
| 2 | Drain removed refrigerant compressor | ||
| Checking | |||
| 3 | Check condition of compressor oil | ||
| Measure | |||
| 4 | Measure quantity of compressor oil drained from removed refrigerant compressor | ||
| Fill | |||
| 5 | Fill new refrigerant compressor |