Remove/Install Starter Front-End Relay - AR54.10-P-0015LW
Model 205
Model 213
Model 238
Model 253 (except 253.992/993)
| Risk of explosion from explosive gas. Risk of poisoning and caustic burns from swallowing battery electrolyte. Risk of injury through burns to skin and eyes from battery acid or when handling damaged lead-acid batteries | No fires, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers. | AS54.10-Z-0001-01A | |
| Notes on battery | AH54.10-P-0001-01A | ||
| Notes on safety-relevant components | AH00.00-Z-0019-01A | ||
| Remove/install | |||
| 1 | Detach ground line of on-board electrical system battery | Model 205, 213, 253 (except 253.992/993) | AR54.10-P-0003LW |
| Model 238 | AR54.10-P-0003LWO | ||
| 2 | Remove cover (2) | ||
| 3 | Release battery clamp (6) | *BA54.10-P-1010-01A | |
| 4 | Remove electrical lines (4, 5) from front-end relay (1) and place to one side Notes on self-locking nuts and bolts | AH00.00-N-0001-01A | |
| *BA54.10-P-1009-01A | |||
| 5 | Remove front-end relay (1) and disconnect electrical connector (3) | ||
| 6 | Install in the reverse order |
BATTERY
| Number | Designation | Model 205 | Model 213 | |
|---|---|---|---|---|
| BA54.10-P-1009-01A | Nut, positive line/starter wiring harness to starter series relay | Nm | 16 | 16 |
BATTERY
| Number | Designation | Model 238 | Model 253 | |
|---|---|---|---|---|
| BA54.10-P-1009-01A | Nut, positive line/starter wiring harness to starter series relay | Nm | 16 | 16 |
BATTERY
| Number | Designation | Model 205 | Model 213 | |
|---|---|---|---|---|
| BA54.10-P-1010-01A | Starter series relay to positive terminal | Nm | 6 | 6 |
BATTERY
| Number | Designation | Model 238 | Model 253 | |
|---|---|---|---|---|
| BA54.10-P-1010-01A | Starter series relay to positive terminal | Nm | 6 | 6 |