Remove/Install Expansion Valve - AR83.30-P-5520GQ
MODEL 166, 292
MODIFICATION NOTES
| 05.10.2016 | Safety note added | AS83.00-Z-0006-01A | |
| 13.09.2016 | Compressor oil specification changed | BB00.40-P-0362-01A | |
| 12.09.2016 | General note added | AH83.30-P-0003-02A | |
| 12.09.2016 | General note added | AH83.30-N-0003-01A | |
| 12.09.2016 | General note added | AH83.30-P-0005-01A | |
| 12.09.2016 | Safety note added | AS83.00-Z-0001-01A | |
| 12.09.2016 | Safety note added | AS83.00-Z-0007-01A |
Shown on model 166
| Risk of fire due to ignition of R1234yf refrigerant on hot components. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with escaped R1234yf refrigerant and when working on pressurized parts. Risk of explosion due to formation of ignitable refrigerant/air mixtures | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. Model 166, 292 with code 2U8 (Alternative refrigerant) |
AS83.00-Z-0007-01A | |
| Risk of poisoning caused by inhaling overheated refrigerant vapors from an air conditioning system containing R134a. Risk of injury to skin and eyes caused by contact with liquid R134a refrigerant and when working on pressurized parts | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. Model 166, 292 except code 2U8 (Alternative refrigerant) |
AS83.00-Z-0006-01A | |
| Protect air conditioning circuit and components from moisture when carrying out repair work | AH83.30-P-0005-01A | ||
| Notes on handling refrigerant R1234yf | Model 166, 292 with code 2U8 (Alternative refrigerant) | AH83.30-P-0003-02A | |
| Notes on handling refrigerant R134a | Model 166, 292 except code 2U8 (Alternative refrigerant) | AH83.30-N-0003-01A | |
| Remove | |||
| 1 | Drain air conditioning system | AR83.30-P-1760CW | |
| 2 | Remove windshield wiper system | AR82.30-P-6400GZ | |
| 3 | Remove connecting strut at left | If necessary. | |
| 4 | Remove panel (2) | ||
| 5 | Unscrew nuts of low-pressure line (5) and high-pressure line (4) from expansion valve (1) | ||
| 6 | Pull low-pressure line (5) and high-pressure line (4) out from expansion valve (1) and seal with a stop plug | Otherwise, penetrating dirt and moisture will damage the air conditioning system. |
Figure |
| 7 | Remove bolts (3) | ||
| 8 | Lift seal (6) (arrow) and remove expansion valve (1) | ||
| 9 | Seal openings on air conditioner housing using suitable stop plugs | Otherwise, penetrating dirt and moisture will damage the air conditioning system. |
Figure |
| Install | |||
| 10 | Remove stop plug from air conditioner housing | Figure | |
| 11 |
Insert sealing rings of expansion valve (1) and moisten with compressor oil Compressor oils (specification 362.1) | BB00.40-P-0362-01A | |
| 12 | Lift seal (6) (arrow) and insert expansion valve (1) | ||
| 13 |
Moisten screws/bolts (3) for expansion valve (1) with compressor oil and apply in alternating fashion Compressor oils (specification 362.1) | BB00.40-P-0362-01A | |
| 14 | Tighten screws/bolts (3) for expansion valve (1) | *BA83.30-P-1006-01J | |
| 15 | Remove stop plugs from low-pressure line (5) and high-pressure line (4) | Figure | |
| 16 |
Insert sealing rings on low-pressure line (5) and high-pressure line (4) and moisten with compressor oil Compressor oils (specification 362.1) | BB00.40-P-0362-01A | |
| 17 | Insert low-pressure line (5) and high-pressure line (4) in expansion valve (1) | ||
| 18 | Tighten nuts of low-pressure line (5) and high-pressure line (4) at expansion valve (1) | Nut, low- and high-pressure lines to expansion valve | *BA83.30-P-1004-01J |
| 19 | Install paneling (2) | ||
| 20 | Install left connecting strut | If removed. | |
| 21 | Install windshield wiper system | AR82.30-P-6400GZ | |
| Check | |||
| 22 | Evacuate the air conditioning system, refill it, and then check the system to make sure that it functions correctly and does not leak | AR83.30-P-1760CW |
AIR CONDITIONING
| Number | Designation | Model 166 | Model 292 | |
|---|---|---|---|---|
| BA83.30-P-1004-01J | Nut, low- and high-pressure lines to expansion valve | Nm | 8 | 8 |
AIR CONDITIONING
| Number | Designation | Model 166 | Model 292 | |
|---|---|---|---|---|
| BA83.30-P-1006-01J | Bolt, expansion valve to retaining plate | Nm | 5 | 5 |