000 588 03 21 00 Gas Detector - WS47.00-P-0019B
MODEL ALL
Use in FG 47/Set B Purpose:
Hydrogen gas detection unit to measure the hydrogen concentration, for example to determine leakages on the A/C in combination with forming gas (95 % nitrogen, 5 % hydrogen) or to establish leakages on hydrogen plant.
Test equipment category CAT_B.
Technical Note:
Leak location on A/Cs in combination with the leaktightness testing device W 000 588 19 21 00 (smart, cars, vans BO-duty/without any exemption).
Procurement information:
This criteria catalog serves to provide support for selection of variants of workshop equipment available on the free market. It just describes the minimum requirement for fulfilling the Mercedes-Benz standard. There is therefore no reference made to manufacturer specific equipment or devices.
The gas detection unit can usually be used for leaktightness testing device released by the manufacturers or be selected on the basis of the criteria catalog on the free market.
Minimum requirements:
- Measuring range at least 10 ppm to 500 ppm.
- Measurement value display: the hydrogen concentration is output in an increment less than or equal to 10 ppm.
- The measuring tip is attached to a flexible extension (gooseneck).
- The device produces acoustic feedback regarding the hydrogen concentration for the user.