Check Battery - AR54.10-P-1129-01A
Model 117, 124, 126, 129, 140, 156, 163, 164, 166, 168, 169, 170, 171, 172, 176, 199, 201, 202, 203, 204, 207, 208, 209, 210, 211, 212, 215, 216, 218, 219, 220, 221, 230, 231, 240, 242, 245, 246, 251, 292, 451, 453, 461, 463
Model 190
except code U98 (LITHIUM-IONEN-STARTERBATTERIE (LISB))
Model 197
except code P98 (Black Series)
Model 205
except code P25 (BlueEFFICIENCY Edition)
except code U98 (LITHIUM-IONEN-STARTERBATTERIE (LISB))
Model 213, 238, 253
except code U98 (LITHIUM-IONEN-STARTERBATTERIE (LISB))
Model 217 (except 217.37/47)
Model 222 (except 222.077/176/177/178/179/187/188)
Model 257
Model 290
Model 293
| 10.05.2019 | Battery capacity 70 Ah VRLA/AGM | BE54.10-P-1010-01A |
| Risk of fire /risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning caused by swallowing battery electrolyte or absorption of lead through the skin or orifices. Risk of death due to voltage U >= 25 V AC and U >= 60 V DC. | No fires, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers. | AS54.10-Z-0001-01A | |
| Notes on 12 V/48 V lithium-ion battery | Model 190 except code U98 (LITHIUM-IONEN-STARTERBATTERIE (LISB)) |
||
| Model 197 except code P98 (Black Series) Model 205 except code P25 (BlueEFFICIENCY Edition) except code U98 (LITHIUM-IONEN-STARTERBATTERIE (LISB)) Model 213, 238, 253 except code U98 (LITHIUM-IONEN-STARTERBATTERIE (LISB)) Model 217 (except 217.37/47) Model 222 (except 222.077/176/177/178/179/187/188) Model 257, 290 |
AH54.10-P-0004-01A | ||
| Notes on battery | AH54.10-P-0001-01A | ||
| 000 588 02 19 00 Battery tester | WS54.00-N-3006B |
| Number | Designation | Model all (4xWD, CAR, smart) | |||
|---|---|---|---|---|---|
| BE54.10-P-1006-01A | Battery capacity 60 Ah VRLA/AGM | Cold cranking amps | As per EN | A | 660 |
| Number | Designation | Model all (4xWD, CAR, smart) | |||
|---|---|---|---|---|---|
| BE54.10-P-1010-01A | Battery capacity 70 Ah VRLA/AGM | Cold cranking amps | As per EN | A | 720 |
| Number | Designation | Model all (4xWD, CAR, smart) | |||
|---|---|---|---|---|---|
| BE54.10-P-1012-01A | Battery capacity 80 Ah VRLA/AGM | Cold cranking amps | As per EN | A | 800 |
| Number | Designation | Model all (4xWD, CAR, smart) | |||
|---|---|---|---|---|---|
| BE54.10-P-1015-01A | Battery capacity 95 Ah VRLA | Cold cranking amps | As per EN | A | 850 |
Whenever possible, perform the tests with the battery still installed and connected.
If, when testing, the battery tester shows a "Surface voltage detected" message, this indicates an increased voltage.
- Switch off ignition and store transmitter key outside of transmitter range (min. 2 m).
- Switch off lighting and audio components.
- Connect battery tester to battery.
Do not connect battery tester to jump start or charging terminal point; always connect it directly to the battery.
Otherwise the test result may be incorrect.
Once the battery tester has been connected the currently measured battery voltage is displayed.
For system noise.
↓
Wait for approx. 2 minutes until the bus systems are switched off and the quiescent current is minimized.
- Conduct test procedure according to battery test device menu navigation.
- After the test print out the test code displayed and store it safely in a tamperproof manner.