LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2016 >> G550 >> Repair and Diagnosis >> Suspension >> Rear Suspension >> Rear Axle - 463 Chassis >> Testing & Repair >> Carry Out Concentricity Measurement On The Drive Flange >> Carry Out Concentricity Measurement On The Drive Flange - AR35.30-P-4671-02A

Carry Out Concentricity Measurement On The Drive Flange - AR35.30-P-4671-02A

MODEL 460 

MODEL 461 (except 461.331) 

MODEL 463 (except 463.270/271) 

up to model year 2013 

REFER TO SHOP-MADE TOOLS Base plate for measuring tripod WF58.50-P-3330-04A
Fig 1: Identifying Measuring Flange (460 589 01 23 00)
G13668282Courtesy of MERCEDES-BENZ USA
Fig 2: Identifying Dial Gauge (001 589 53 21 00)
G13668283Courtesy of MERCEDES-BENZ USA
Fig 3: Identifying Dial Indicator Holder (363 589 02 21 00)
G13668284Courtesy of MERCEDES-BENZ USA
  1. SPECIAL TOOL Attach measuring flange to flange (1).
  2. SPECIAL TOOL Mount dial indicator holder and SPECIAL TOOL Mount dial indicator on transmission housing.
  3. Position dial indicator on front measuring surface of measuring flange.
  4. Turn the flange (1) through one complete rotation and measure the total concentricity.
    G13668285Courtesy of MERCEDES-BENZ USA