LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2016 >> E400 Base, 2D Convertible >> Repair and Diagnosis >> General Information >> OEM General Information >> Overall Vehicle - 212 Chassis - 4 Of 7 >> Testing & Repair >> Remove contacts from standard power timer connector - AR00.19-P-0120-11A

Remove contacts from standard power timer connector - AR00.19-P-0120-11A

MODEL ALL 

Fig 1: Identifying Passenger Vehicle Wiring Harness Repair Kit (220 589 04 99 00)
G10240316Courtesy of MERCEDES-BENZ USA
Fig 2: Identifying Wiring Harness Repair Kit, Basic (000 589 13 99 00)
G10240317Courtesy of MERCEDES-BENZ USA
Fig 3: Identifying Blade Holder With Clamping Pliers (220 589 01 99 50)
G10240318Courtesy of MERCEDES-BENZ USA
Fig 4: Identifying JPT/SPT Blade (220 589 01 99 61)
G10240319Courtesy of MERCEDES-BENZ USA
Fig 5: Identifying MCP 2.8/Fl Blade. 2.8/JPT/SPT (000 589 13 99 30)
G10240320Courtesy of MERCEDES-BENZ USA

Unpin contact pin from connector 

  1. Insert blade holder with SPECIAL TOOL clamping pliers with SPECIAL TOOL JPT/SPT blade or SPECIAL TOOL MCP 2.8/Fl. 2.8/JPT/SPT blade from front side through openings at contact cavity of connector (1).

    IMPORTANT This presses together the spring shackles (2) on the contact pin (3).

  2. Pull lightly on the corresponding line to remove the contact pin (3) from the plug (1).
    Fig 6: Removing Contact Pin From Plug
    G10240321Courtesy of MERCEDES-BENZ USA