LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2016 >> E400 Base, 2D Convertible >> Repair and Diagnosis >> Electrical >> Motors, Switches, Relays >> Electrical System - Body - 207 Chassis - 2 Of 4 >> Basic Knowledge >> Emergency call system control unit, component description - GF82.95-P-3212CAU

Emergency call system control unit, component description - GF82.95-P-3212CAU

MODEL 207 with CODE (359) TELEAID emergency call system 

Illustrated on model 207.3 

Fig 1: Identifying Emergency Call System Control Unit Components - Illustrated On Model 207.3
G10082008Courtesy of MERCEDES-BENZ USA

Location 

The emergency call system control unit is located in the trunk under the trunk mat on the crossmember.

Task 

The emergency call system control unit has the following tasks:

Realization of vehicle-related services 

Realization of following vehicle-related services:

Regulation of priorities via integrated priority management 

Priority Service
1 Automatic emergency call
2 Manual emergency call
3 Vehicle tracking
4 Roadside assistance
5 MB information call
6 Authorization
7 Vehicle remote door unlock or vehicle remote door lock

Communication management between vehicle and service center 

Communication management between vehicle and service center over integrated communication module and national mobile telephone network as well as transmission of information to driver if required.

Forwarding vehicle position and identification as well as other required data to the service center 

Audio management 

Display management 

Fault handling 

After activation of circuit 15R, the emergency call system control unit performs a self-test (for approx. t = 4 s). If the self-test is successful, the emergency call system is then ready for operation.

In the event of a fault, a fault message is displayed on the instrument cluster, depending on the fault type, and the two red light-emitting diodes (LED) in the emergency call system button are permanently actuated. Depending on the fault type, the fault is also stored in the emergency call system control unit's memory.

Receive signals 

Signals are read in via the following connections:

Direct lines 

CAN 

The emergency call system control unit receives signals via diagnostic CAN (CAN D). The functions that use these signals are described in the individual function descriptions.

Transmit signals 

The signals are transmitted via the following connections:

Direct lines 

CAN 

The emergency call system control unit transmits the signals via diagnostic CAN

The functions that use these signals are described in the individual function descriptions.

Design 

Function 

The emergency call system control unit has its own microprocessor. A differentiation is made between the two subareas of the communication module and the locating module. The emergency call system control unit centrally processes all the vital data for the listed vehicle-related services.

The emergency call system control unit uses the installed locating module to calculate the vehicle position.

The emergency call system control unit generates the data telegram in the form of an SMS if one of the following vehicle-related services is activated:

The communication module integrated into the emergency call system control unit is a mobile phone transceiver enabling voice and data communication with the service center over mobile phone frequencies. This supports communication via the two American mobile telephone networks: the analog Advanced Mobile Phone Service (AMPS) network and the digital Code Division Multiple Access network ("CDMA network"). For data communication in the AMPS network, the communication module is also equipped with a modem.

Properties:

IMPORTANT In the event of a multifunction antenna malfunction (e.g. defective because of rollover) the emergency call system control unit automatically uses the emergency call system antenna to receive and transmit mobile phone signals.

Other functions of the communication module are:

Technical data
Designation
Unit Values Tolerance range Remarks
Emergency call system control unit         
Power supply V 13 ±1 (UB) accomplished over circuit 15R
Voltage limits V 9 ±1 Minimum (UBmin )
  V 16 ±1 Maximum (UBmax )
Power consumption μA ≤360   Sleep mode (unit deactivated, "Circuit 30 OFF"); (Advanced Mobile Phone Service (AMPS) and Code Division Multiple Access (CDMA))
Typical (Ityp )
μA 400   Sleep Mode (unit deactivated, "Circuit 30 OFF"); (AMPS and CDMA)
Maximum (Imax )
mA ≤3   Stand-by mode (up to 4 days after "Circuit 15 OFF"; Network Access Device (NAD) activated); (AMPS and CDMA)
Minimum (Imin .)
mA 12   Stand-by mode (up to 4 days after "Circuit 30 OFF"; NAD activated); (AMPS and CDMA)
Maximum (Imax )
mA 500   Idle mode (unit activated, without current service); (AMPS and CDMA)
Typical (Ityp )
mA 600   Idle mode (unit activated, without current service); (AMPS and CDMA)
Maximum (Imax )
mA 800   Normal mode (unit activated, with current service); (AMPS) Typical (Ityp )
mA 1700   Normal mode (unit activated, with current service); (AMPS)
Maximum (Imax )
mA 650   Normal mode (unit activated, with current service); (CDMA)
Typical (Ityp )
mA 1200   Normal mode (unit activated, with current service); (CDMA)
Maximum (Imax )
mA 650   Send SMS
Typical (Ityp )
mA 500   Receiving SMS
Typical (Ityp )
Reverse polarity protection       The emergency call system control unit is protected for a period of t = 5 minutes against polarity reversal up to maximum U pol. rev. = 36 V, without any damage.
All inputs and outputs on the emergency call system control unit are resistant to short circuit.
Additional specific parameters       None
Special features       The software of the emergency call system control unit processes its routines and commands independently of the connected components. The prioritization of the individual tasks is regulated by the emergency call system control unit. These priorities can be changed and defined only with the management information base (MIB).
Flash capability/coding capability       Yes/yes
Center instrument panel speaker         
Model       Speaker
Bandwidth Hz 250 to 10 000    
Emergency call system button, MB-Info button and breakdown assistance button         
Model       Button group with LEDs
Voltage V 12   LED
Resistor Ω ≈0   Pushbutton operated
Global positioning system antenna splitter        With code (512) COMAND APS with DVD changer or with code (527) COMAND APS with single DVD drive (with navigation)
Model       Antenna splitter
Frequency MHz 1574.4...
1576.447
  From multifunction antenna
Multifunction antenna         
Power supply V 12   Operating voltage (UNom )
Quiescent current mA 1.2   TypicalQuiescent )
  mA 1.5   Maximum (IQuiescent )
Wake-up mA 9   With UB = 12 V (IWake-Up )
Reverse polarity protection       Polarity reversal protection up to UB = 15 V for a period of t = .
Additional specific parameters       The unit can withstand voltage peaks of UB = 27 V over a maximum period of t = 60 s, without suffering any damage.
Special features        
Amplifier output interference voltages dBμV 5   AM maximum (UNoise )
dBμV 8   AM typical (UNoise )
dBμV 4   FM maximum (UNoise )
dBμV 6   FM typical (UNoise )
Output Ω 50   Characteristic impedance (ZA )
Flash capability/coding capability       n/a/n/A.
Emergency call system antenna         
Power supply       n/A.
Quiescent current       n/A.
Additional specific parameters       n/A.
Special features       n/A.
REFER TO SYSTEM WIRING DIAGRAMS Wiring diagram for emergency call system control unit N123/4 PE82.95-P-2101-97EAA