Home >> Mercedes Benz >> 2016 >> CLS400 4Matic >> Repair and Diagnosis >> External Pages >> Different car >> Section 102 (Climate Control - General Information) >> General Information >> Protect air conditioning circuit and components from moisture when carrying out repair work >> Protect air conditioning circuit and components from moisture when carrying out repair work - AH83.30-P-0005-01GW

Protect air conditioning circuit and components from moisture when carrying out repair work - AH83.30-P-0005-01GW

WARNING: This page does not describe the selected car, but rather 203 other vehicles, including the 2020 Mercedes-Benz SLC300, 2020 Mercedes-Benz SL550, 2020 Mercedes-Benz SL450, 2020 Mercedes-Benz S65 AMG, and 2020 Mercedes-Benz GLA250. However, it is still accessible from the selected car via links, so may be relevant.

MODEL 461, 463 as of model year 2013 

NOTES

NOTES Do not carry out any repair operations on the refrigerant circuit in the A/C when outdoors in humid weather.

Moisture in the refrigerant circuit reduces the system's refrigeration output and leads to damage to the components.

After disconnecting or unscrewing refrigerant lines, immediately seal all connection apertures air tight with suitable plugs.

The fluid reservoir or the desiccant cartridge are to be replaced when:

Always store all spare components in a dry, sealed-off area. Do not remove stop plugs in new components until just before they are installed.

Check drier cartridge packaging for damage. Dispose of drier cartridges with damaged packaging.

Install the desiccant cartridge no later than 20 minutes after opening the packaging.

Further protection against moisture is provided by carefully evacuating the air conditioning system following repair operations. The evacuation process (the generation of vacuum in the system) removes any moisture that might have penetrated into the system.