Prepare Reinforcement And Panel Of B-Pillar In Area Of Lock Striker - SM63.20-D-0009-01A
Model 906.1
- Trial-fit B-pillar reinforcement (1) in installation position several times.
- Remove B-pillar reinforcement (1).
For reasons of clarity, the B-pillar is shown without the inner panel.
- Mark holes on B-pillar panel.
Dimensions:
a = 15 mm
b = 35 mm
- Drill holes in B-pillar panel with Ø 8 mm drill bit and deburr.
- Position B-pillar reinforcement in installation position.
- Transfer holes from B-pillar panel to B-pillar reinforcement.
- Remove B-pillar reinforcement.
- Drill holes in B-pillar reinforcement with Ø 3.7 mm drill bit.
- Position B-pillar reinforcement in installation position.
- Fasten B-pillar reinforcement temporarily with bolts (2).
The B-pillar reinforcement must lie on the B-pillar panel without gaps.
- Unscrew bolts (2).
- Remove B-pillar reinforcement.