Test Specifications For Vacuum Pump - Be43.05-N-1000-01C
MODEL 906
CHECK VALUES FOR CHECK VALVE/VACUUM PUMP
| Number |
Designation |
Model 906 |
| BE43.05-N-1001-01C |
Vacuum in hose after engine has been running for 30 seconds |
at check valve |
bar |
≥0, 5 |
| at vacuum pump |
bar |
≥0, 92 |
| BE43.05-N-1002-01C |
Vacuum in hose after 10 min engine OFF |
at check valve |
bar |
≥0, 3 |