LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2015 >> SLK350 >> Repair and Diagnosis >> Collision >> Sealing & Corrosion Protection >> Body Sealing, Corrosion Protection - 172 Chassis >> Testing & Repair >> Cavity preservation following repair work - AR97.20-P-1500W

Cavity preservation following repair work - AR97.20-P-1500W

MODEL 172 

Fig 1: Identifying Cavity Preservation Methods
G10248737Courtesy of MERCEDES-BENZ USA

Engine hood 

Fig 2: Identifying Engine Hood Repair Work Area
G10248738Courtesy of MERCEDES-BENZ USA

Liftgate 

Fig 3: Identifying Liftgate Repair Work Area
G10248739Courtesy of MERCEDES-BENZ USA

Front fender 

Fig 4: Identifying Front Fender Repair Work Area
G10248740Courtesy of MERCEDES-BENZ USA

Door 

Fig 5: Identifying Door Repair Work Area
G10248741Courtesy of MERCEDES-BENZ USA

Front crossmember 

Fig 6: Locating Front Crossmember Repair Work Area
G10248742Courtesy of MERCEDES-BENZ USA

Front longitudinal member 

Fig 7: Locating Front Longitudinal Member Repair Work Area
G10248743Courtesy of MERCEDES-BENZ USA

Front longitudinal member, A-pillar, side wall paneling and side longitudinal member 

Fig 8: Locating Front Longitudinal Member, A-Pillar, Side Wall Paneling, Side Longitudinal Member Repair Work Area
G10248744Courtesy of MERCEDES-BENZ USA

Inner firewall 

Fig 9: Locating Inner Firewall Repair Work Area
G10248745Courtesy of MERCEDES-BENZ USA

Rear longitudinal member 

Fig 10: Locating Rear Longitudinal Member Repair Work Area
G10248746Courtesy of MERCEDES-BENZ USA

Rear end 

Fig 11: Locating Rear End Repair Work Area
G10248747Courtesy of MERCEDES-BENZ USA

Underfloor 

Fig 12: Locating Underfloor Repair Work Area
G10248748Courtesy of MERCEDES-BENZ USA
Picture item, etc.  Work instructions     
DANGER Risk of explosion  and poisoning  caused by solvent vapors and gasses. Risk of injury  to skin and eyes when handling anticorrosion agents. Never spray anticorrosion agents on flames or glowing hot objects and keep them well away from all potential sources of ignition. Use them only in well-ventilated rooms; wear respiratory protection. AS97.00-Z-0001-01A
NOTES Notes on cavity preservation   AH97.20-P-0001-01B
REFER TO AUXILIARY REPAIR MATERIALS Cavity preservation, solvent-free (1 l container)   *BR00.45-Z-1003-05A 
A Cavity preservation in area of crimp IMPORTANT Apply from inside with hook nozzle Apply cavity preservation with spraying hose and nozzle (spraying angle 360°) as far as possible into cavities.  
B Inner surface, cavities and gaps IMPORTANT Uniformly moisten cavity preservation.  
REPAIR MATERIALS

Number Designation Order number
BR00.45-Z-1003-05A Cavity sealant, solvent-free (1 l container) A 000 986 72 70 05