LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2015 >> SL400 >> Repair and Diagnosis >> Electrical >> Motors, Switches, Relays >> Electrical System, Equipment & Instruments - 231 Chassis >> Testing & Repair >> Charge battery - AR54.10-P-1130RK

Charge battery - AR54.10-P-1130RK

MODEL 231 

Fig 1: Connecting Charger Positive Terminal To Jump Start Connection (Z170Z1)
G11128940Courtesy of MERCEDES-BENZ USA
DANGER Risk of explosion  from explosive gas. Risk of poisoning and caustic burns  from swallowing battery electrolyte. Risk of injury  through burns to skin and eyes from battery acid or when handling damaged lead-acid batteries No fires, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses.
Only pour battery acid into suitable and appropriately marked containers.
AS54.10-Z-0001-01A
NOTES Notes on battery   AH54.10-P-0001-01A
IMPORTANT Notes on AGM battery   AH54.10-P-0002-01A
INSPECT Check     
1 Check condition of on-board electrical system battery (G1) Not with active transport mode. AR54.10-P-1129RK 
2 Push dust cap (1) in downward direction With on-board electrical system battery (G1) installed.  
  Charging     
3.1
REFER TO SPECIAL TOOLS
Connect charger to positive and negative terminal of on-board electrical system battery (G1)
000 588 00 81 00 Charger
With on-board electrical system battery (G1) removed.
NOTES
Do not reverse polarity.
Damage caused by short circuits will otherwise occur.
WS54.00-P-0037B 
3.2
REFER TO SPECIAL TOOLS
Connect charger positive terminal (3) to jump start connection (Z170z1) and charger ground terminal (4) to ground terminal point (2)
000 588 00 81 00 Charger
With on-board electrical system battery (G1) installed.
NOTES
Do not reverse polarity.
Damage caused by short circuits will otherwise occur.
WS54.00-P-0037B 
4
REFER TO SPECIAL TOOLS
Charge on-board electrical system battery (G1)
000 588 00 81 00 Charger
  WS54.00-P-0037B 
    IMPORTANT The battery charging period depends on the charge level of the discharged on-board electrical system battery (G1).
The on-board electrical system battery (G1) must be charged using an approved charger (see WS54.00-P-0037B ).
The on-board electrical system battery (G1) is sufficiently charged when the charging current reading is < 25 A. 
 
5
REFER TO SPECIAL TOOLS
Disconnect charger from on-board electrical system battery (G1)
000 588 00 81 00 Charger
NOTES
It is essential to switch off the charger first. Arcing can otherwise occur.
IMPORTANT Press on the dust cap (1) lightly and detach the charger positive terminal (3).
A spring mechanism pushes the dust cap (1) up automatically.
WS54.00-P-0037B 
INSPECT Check     
6 Check condition of on-board electrical system battery (G1) Not with active transport mode. AR54.10-P-1129RK