DC/AC converter function - GF54.10-P-2005GR
MODEL 166 up to model year 2016 with CODE U80 (115 V socket)
Function requirements, general
- Circuit 15R ON
The electronic ignition switch control unit (N73) transmits the circuit status c. 15 via the interior CAN (CAN B).
DC/AC converter, general
Small electrical devices that require supply with U = 115 V AC voltage can be connected to the 115 V power outlet (X58/34).
Function sequence for DC/AC converter
The SAM control unit (N10) controls the function of the DC/AC converter control unit (N24/3). When a consumer is connected to the 115 V socket, it is detected by the microswitch power outlet (X58/34s1). The SAM control unit supplies power to the microswitch power outlet.
If a consumer is connected to the 115 V power outlet, this voltage is switched through to the control input of the DC/AC converter control unit. The DC/AC converter control unit converts the DC voltage of the on-board electrical system into AC voltage. An LED integrated into the 115 V power outlet indicates the availability of AC voltage.
The maximum available electrical continuous load is P = 150 W, for a short-term up to P = 300 W is permissible for t = 2 s.
If the interior temperature of the DC/AC converter control unit rises above a defined limit value or if the output load exceeds the overload threshold of P = 160 W for t = 2s, the DC/AC converter control unit switches off.
The DC/AC converter control unit prevents the inverter from constantly switching between on and off when it approaches the limit value.
If undervoltage is detected by the energy management system, the DC/AC converter control unit is switched off and the power supply to the 115 V power outlet is interrupted.
| Electrical function schematic for DC/AC converter | PE54.10-P-2055-97NAA | ||
| Overview of energy management system components | GF54.10-P-9990GR |