Remove/Install 360° Camera In Outside Mirror - AR54.30-P-3002GQ
MODEL 166 with CODE 501 (360 degree camera)
Shown on model 166.873
| Remove/install | |||
| Information on preventing damage to electronic components due to electrostatic discharge | AH54.00-P-0001-01A | ||
| 1 | Switch off ignition | ||
| 2 | Remove upper cover of corresponding outside mirror | AR88.70-P-9040RTA | |
| 3 | Release and disconnect electrical connector (1) | ||
| 4 | Remove screw/bolt (2) | ||
| 5 | Carefully disengage camera, 360° camera for left outside mirror (B84/7) or camera 360° camera for right outside mirror (B84/8) from lower cover (arrow) of outside mirror and then remove | The lens will otherwise be damaged. |
|
| 6 | Install in the reverse order | ||
| 7 | Calibrate 360° camera for left outside mirror (B84/7) or 360° camera for right outside mirror (B84/8) using Star Diagnosis | ||
| AD00.00-P-2000-04A |