Remove/install control and operating unit - AR83.40-P-6350GY
MODEL 463.202 /222 /236 /237, 463.247 /248 /254 /270 /271 /303 /340 /341 as of 2.4.07 AAC [KLA] control and operating unit
MODEL 463.249 as of 1.9.06 AAC [KLA] control and operating unit
MODEL 463.306 /336 /346 AAC [KLA] control and operating unit
| Remove/install | |||
| 1 | Remove ashtray housing (1) | AR68.20-P-2400GM | |
| Risk of explosion caused by oxyhydrogen gas. Risk of poisoning and caustic burns caused by swallowing battery acid. Risk of injury caused by burns to skin and eyes from battery acid or when handling damaged lead-acid batteries | No fire, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers. | AS54.10-Z-0001-01A | |
| 2 | Disconnect battery ground line | Except model 463.236/248 with code (979) Special protection version | AR54.10-P-0003G |
| Model 463.236/248 with code (979) Special protection version, with code (ZS6) Special protection version FB6, with code (E26) Additional battery 100 Ah incl. cutoff relay Model 463.236/248 with code (979) Special protection version, with code (ZS7) Special protection version FB7, with code (E26) Additional battery 100 Ah incl. cutoff relay |
AR54.10-P-0003PM | ||
| Notes on battery | AH54.10-P-0001-01A | ||
| 3 | Remove AAC pushbutton control unit (N22) | ||
| 4 | Disconnect electrical connectors | ||
| 5 | Install in the reverse order | ||
| 6 | Synchronize automatic air conditioning actuator motors | ||
| Connect STAR DIAGNOSIS and read out fault memory | AD00.00-P-2000-04A | ||
| 7 | Read out fault memory and erase | Stored faults which may be caused by removed cables or by a simulation, must be processed and erased in the fault memories after completing the work. |
|
| Connect STAR DIAGNOSIS and read out fault memory | AD00.00-P-2000-04A |