Cavity preservation following repair work - AR97.20-P-1500EW

MODEL 212.0/1 

Engine hood 

Fig 1: Engine Hood Cavity Preservation
G09978139Courtesy of MERCEDES-BENZ USA

Liftgate 

Fig 2: Liftgate Cavity Preservation
G07880208Courtesy of MERCEDES-BENZ USA

Front door 

Fig 3: Front Door Cavity Preservation
G09978141Courtesy of MERCEDES-BENZ USA

Rear door 

Fig 4: Rear Door Cavity Preservation
G09978142Courtesy of MERCEDES-BENZ USA

Upper front longitudinal member, A-pillar, B-pillar, C-pillar, side wall paneling and bottom side longitudinal member 

Fig 5: Upper Front Longitudinal Member, A-Pillar, B-Pillar, C-Pillar, Side Wall Paneling And Bottom Side Longitudinal Member Cavity Preservation
G09978143Courtesy of MERCEDES-BENZ USA

Front longitudinal member 

Fig 6: Front Longitudinal Member Cavity Preservation
G09978144Courtesy of MERCEDES-BENZ USA

Rear longitudinal member 

Fig 7: Rear Longitudinal Member Cavity Preservation
G09978145Courtesy of MERCEDES-BENZ USA

Rear end 

Fig 8: Rear End Cavity Preservation
G09978146Courtesy of MERCEDES-BENZ USA

Under floor 

Fig 9: Under Floor Cavity Preservation
G09978147Courtesy of MERCEDES-BENZ USA
DANGER Risk of explosion  and poisoning caused by solvent vapors and gasses. Risk of injury  to skin and eyes when handling anticorrosion agents. Never spray anticorrosion agents on flames or glowing hot objects and keep them well away from all potential sources of ignition. Use them only in well-ventilated rooms; wear respiratory protection. AS97.00-Z-0001-01A
NOTES Notes on cavity preservation   AH97.20-P-0001-01B
1 Perform repair preservation IMPORTANT Apply cavity sealant from inside in crosshatched areas following sealing and paintwork, however, before performing assembly work. Apply repair preservation agent twice with a drying time of 5 minutes in between.
IMPORTANT The spraying hose should be stiff and the nozzles should spray at angle to the front and rear. The cavities should be dry.
IMPORTANT Insert spray hoses as far as possible into cavities. Spray while inserting and pulling out slowly.
 
REFER TO MAINTENANCE Processing instructions for cavity preservation agent   AP97.20-P-0640-01A
REFER TO BASIC KNOWLEDGE Cavity protection, general   GF98.00-P-2045A
    Preservation agent *BR00.45-Z-1003-05A 
2 Remove cavity sealant from drain holes IMPORTANT The processing temperature should not be less than 15 °C. Additional preservation measures may be required, depending on the repair area, deviating from the standard cavity preservation shown.  
REPAIR MATERIALS

Number Designation Order number
BR00.45-Z-1003-05A Cavity preservation, solvent-free (1 l container) A 000 986 72 70 05