Cavity preservation following repair work - AR97.20-P-1500EW
MODEL 212.0/1
Engine hood
Liftgate
Front door
Rear door
Upper front longitudinal member, A-pillar, B-pillar, C-pillar, side wall paneling and bottom side longitudinal member
Fig 5: Upper Front Longitudinal Member, A-Pillar, B-Pillar, C-Pillar, Side Wall Paneling And Bottom Side Longitudinal Member Cavity Preservation
Front longitudinal member
Rear longitudinal member
Rear end
Under floor
| Risk of explosion and poisoning caused by solvent vapors and gasses. Risk of injury to skin and eyes when handling anticorrosion agents. | Never spray anticorrosion agents on flames or glowing hot objects and keep them well away from all potential sources of ignition. Use them only in well-ventilated rooms; wear respiratory protection. | AS97.00-Z-0001-01A | |
| Notes on cavity preservation | AH97.20-P-0001-01B | ||
| 1 | Perform repair preservation | ||
| Processing instructions for cavity preservation agent | AP97.20-P-0640-01A | ||
| Cavity protection, general | GF98.00-P-2045A | ||
| Preservation agent | *BR00.45-Z-1003-05A | ||
| 2 | Remove cavity sealant from drain holes |
REPAIR MATERIALS
| Number | Designation | Order number |
|---|---|---|
| BR00.45-Z-1003-05A | Cavity preservation, solvent-free (1 l container) | A 000 986 72 70 05 |