Retrofit illuminated door sill molding - AZ82.20-P-0001LW
Model 205.0 (except 205.012/047/064/086/087)
Model 205.2 (except 205.212/247/264/286/287)
MODIFICATION NOTES
| 26.9.14 | Electrical line bridge added | Operation steps 11 to 16 | AZ82.20-P-0001-04LW |
| Information on preventing damage to electronic components due to electrostatic discharge | AH54.00-P-0001-01A | ||
| Remove | |||
| 1 | Move driver seat and front passenger seat towards rear | ||
| 2 | Disconnect battery ground line | ||
| AR54.10-P-0003LW | |||
| 3 | Remove left and right front inner door sills | ||
| 4 | Remove cover below left of instrument panel | ||
| AR68.10-P-1500LW | |||
| 5 | Remove cover below right dashboard | ||
| AR68.10-P-1520LW | |||
| 6 | Remove side paneling of instrument panel at left | ||
| 7 | Remove left and right front door sills | ||
| Fig 2 | |||
| 8 | Remove front left floor covering | ||
| AR68.20-P-2050LW | |||
| 9 | Remove front right floor covering | ||
| AR68.20-P-2070LW | |||
| Install | |||
| 10 | Retrofit illuminated door sill molding wiring harness (2) | AZ82.20-P-0001-04LW | |
| *BA00.19-P-1019-01E | |||
| 11 | Retrofit left front illuminated door sill molding (E17/47) and right front illuminated door sill molding (E17/48) | AZ82.20-P-0001-01LW | |
| 12 | Retrofit illuminated door sill molding control unit (1) | AZ82.20-P-0001-05LW | |
| Self-adhesive Velcro fastener | *BR00.45-Z-1084-02A | ||
| 13 | Install remaining parts | ||
| Update Vehicle Documentation (VeDoc) | |||
| 14 | Attach a note "Illuminated door sill moldings retrofitted as per AZ82.20-P-0001LW " under field organization texts for DG 68 and DG 82 | ||
| Check | |||
| 15 | Perform function check on left front illuminated door sill molding (E17/47) and right front illuminated door sill molding (E17/48) | The left front illuminated door sill molding (E17/47) or right front illuminated door sill molding (E17/48) switches off automatically approx. 5 min after opening the respective door. |
GROUND POINTS
| Number | Designation | Model 205 | ||
|---|---|---|---|---|
| BA00.19-P-1019-01E | Right front footwell ground point (CAN) | W15/8 | Nm | 10 |
REPAIR MATERIALS
| Number | Designation | Order number |
|---|---|---|
| BR00.45-Z-1084-02A | Self-adhesive Velcro fastener |
PARTS ORDERING NOTE
| Part no. | Designation | Quantity |
|---|---|---|
| KG 98 (please refer EPC) | Scope of supply of illuminated door sill moldings | 1 |
| KG 98 (please refer EPC) | Electrical line bridge | 1 |