Check Condition Of Battery - AR54.10-P-1129GZ
MODEL 164, 166
| Check | |||
| Notes on AGM battery | AH54.10-P-0002-01A | ||
| 1 | Visual inspection for external leaks | In the event of leaks: ↓ Replace battery. |
AR54.10-P-0005GZ |
| Risk of explosion from explosive gas. Risk of poisoning and caustic burns from swallowing battery electrolyte. Risk of injury through burns to skin and eyes from battery acid or when handling damaged lead-acid batteries | No fires, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers. |
AS54.10-Z-0001-01A | |
| 2 | Check battery | Cold cranking amps as per EN | |
| Battery capacity 70 Ah VRLA | AR54.10-P-1129-01A | ||
| Battery capacity 95 Ah VRLA | *BE54.10-P-1010-01A | ||
| Battery tester 0 | *BE54.10-P-1015-01A | ||
| Risk of explosion from explosive gas. Risk of poisoning and caustic burns from swallowing battery electrolyte. Risk of injury through burns to skin and eyes from battery acid or when handling damaged lead-acid batteries | No fires, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers. | AS54.10-Z-0001-01A | |
| 3 | Reduce increased voltage after charging process | On a battery that is disconnected from the on-board electrical system and with the message "Surface voltage" in the display of the Midtronics battery tester and analyzer MCR 717 | |
| AR54.10-P-1129-03A | |||
Stress tester.3 Battery tester 0 |
|||
| 4 | Charge battery | If test code "Charge and test" is displayed on Midtronics battery tester and analyzer MCR 717 | |
| AR54.10-P-1130GZ | |||
TEST AND ADJUSTMENT VALUES FOR BATTERY
| Number | Designation | MODEL ALL | |||
|---|---|---|---|---|---|
| BE54.10-P-1010-01A | Battery capacity 70 Ah VRLA | Cold cranking amps | As per EN | A | 760 |
TEST AND ADJUSTMENT VALUES FOR BATTERY
| Number | Designation | MODEL ALL | |||
|---|---|---|---|---|---|
| BE54.10-P-1015-01A | Battery capacity 95 Ah VRLA | Cold cranking amps | As per EN | A | 850 |