LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2014 >> G63 AMG >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Climate Control - 463 Chassis >> Testing & Repair >> Remove/install expansion valve - AR83.30-P-5520GW

Remove/install expansion valve - AR83.30-P-5520GW

MODEL 463 as of model year 2013/model refinement package 2012 

Fig 1: Expansion Valve Remove/Install Components
G10781226Courtesy of MERCEDES-BENZ USA
REMOVINGINSTALLING Remove/install     
1 Remove air conditioner housing   AR83.30-P-5200GW 
NOTES Notes on removing and installing the air conditioner housing   AH83.30-P-0006-01GM
2 Remove gasket (11) IMPORTANT Check seal (11) for damage.  
3 Remove bolts (9) INSTALLATION IMPORTANT to avoid canting, tighten screws (9) alternately.  
    TORQUE SPECIFICATION *BA83.30-P-1016-01C 
4 Remove expansion valve (10) INSTALLATION IMPORTANT Replace sealing rings. Coat thread and sealing rings with compressor oil.  
    SPECIAL TOOL Figure
5 Install in the reverse order    
6 Check air conditioning system for proper function    
7 Check air conditioning circuit for leakage. UV leak detector kit for air conditioning systems
 
 
AIR CONDITIONING

Number Designation Model 463
BA83.30-P-1016-01C Expansion valve bolt Nm 8
Fig 2: Identifying Set Of Stop Plugs (129 589 00 91 00)
G07742724Courtesy of MERCEDES-BENZ USA