Remove/install additional battery - AR54.10-P-0007CW
MODEL 204.0/2/3 with CODE (B03) ECO start/stop function
Shown on model 204.0
| Remove/install | |||
| Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices | No fire, sparks, open flames or smoking. Wear acid-resistant gloves and clothing and safety glasses with side guards. Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground. Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers. |
AS54.10-Z-0001-01A | |
| Notes on battery | AH54.10-P-0001-01A | ||
| Notes on AGM battery | AH54.10-P-0002-01A | ||
| 1 | Switch off all electrical consumers, switch off ignition and remove transmitter key (A8/1) from electronic ignition lock control unit (N73) | ||
| 2.1 | Open luggage compartment floor cover (1) | On model 204.0/3 | |
| 2.2 | Remove rear load compartment floor and intermediate bottom | On model 204.2 | AR68.80-P-5800CX |
| 3.1 | Unclip expansion clip (3) and remove covering from additional battery (2) | On model 204.0/3 | |
| Fig 2 | |||
| 3.2 | Detach spare wheel well trim far enough until the additional battery for the ECO start/stop function (G1/13) is accessible | On model 204.2 | |
| 4 | Remove bolt (4) and detach ground line (5) from additional battery for ECO start/stop function (G1/13) | *BA54.10-P-1004-01F | |
| 5 | Remove cover (6) from positive line (7) | ||
| 6 | Using diode test lamp, check on-board electrical system for voltage between positive line (7) of ECO start/stop function additional battery (G1/13) and a suitable ground point | In this case the ground line of the on-board electrical system battery (G1) should be disconnected. See: ↓ |
|
| Disconnect/connect battery ground line |
AR54.10-P-0003CW | ||
| 7 | Unscrew bolt (8) and remove positive line (7) | *BA54.10-P-1004-01F | |
| 8 | Unscrew nut (10) of bracket (11) | ||
| 9 | Swivel bracket (11) upwards | ||
| 10 | Remove additional battery for ECO start/stop function (G1/13) from battery holder | ||
| 11 | Install in the reverse order |
BATTERY
| Number | Designation | Model 204 | |
|---|---|---|---|
| BA54.10-P-1004-01F | Bolt, battery cable to battery terminal on additional battery | Nm | 5 |