Correct oil level in air conditioning system if system is suddenly drained - AR83.30-P-5253PB
MODEL 204, 207, 212, 216, 218, 221
| Checking | |||
| Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. | AS83.00-Z-0001-01A | |
| Procedure for a damaged or leaky air conditioning system | AH83.30-N-0004-01A | ||
| Protect air conditioning circuit and components from moisture when carrying out repair work | All models with air conditioning | AH83.30-N-0005-01A | |
| Notes on handling R134a refrigerant | All models with R134a refrigerant | AH83.30-N-0003-01A | |
| 1 | Check components for automatic air conditioning for damage | System drained | AR83.30-P-1761PS |
Replace defective component. |
|||
Remove/install desiccant cartridge: |
|||
| Model 216.3, 221.0/1 | AR83.30-P-6520SX | ||
| Fill | |||
| 2 | Connect air conditioning service unit and evacuate/fill air conditioning system | ||
| Correct oil level in air conditioning system after replacing parts. Air conditioner service unit |
AR83.30-P-5252PB | ||
| Model 216, 221 | *BF83.55-P-1002-01H | ||
Model 204, 207, 212, 218 |
*BF83.00-P-1001-01I | ||
| Model 216, 221 | *BF83.00-P-1001-01H | ||
| Checking | |||
| 3 | Check air conditioning system for leakage | System filled | AR83.30-P-1761UV |
AIR CONDITIONING SYSTEM/AUTOMATIC AIR CONDITIONING
| Number | Designation | Model 216 | ||
|---|---|---|---|---|
| BF83.00-P-1001-01H | Filling capacity air conditioning system/automatic air conditioning | Refrigerant R134a | g | 1070 |
| Specifications for Operating Fluids | Sheet | BB00.40-P-0361-00 A |
REFRIGERANT COMPRESSOR
| Number | Designation | Refrigerant compressor in model 216 | ||
|---|---|---|---|---|
| BF83.55-P-1002-01H | Additional oil filling quantity following sudden draining of system (e.g. line ruptured) | Compressor oil | cm3 | 40 |
| Specifications for Operating Fluids | Sheet | BB00.40-P-0362-00 A |