Home >> Mercedes Benz >> 2012 >> Sprinter 2500, Van Passenger >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Climate Control - Basic Knowledge And Safety Precautions - 906 Chassis >> Safety Precautions >> Risk Of Explosion Caused By Welding Or Soldering Work On Closed Air Conditioning System. - As83.00-Z-0001-01A

Risk Of Explosion Caused By Welding Or Soldering Work On Closed Air Conditioning System. - As83.00-Z-0001-01A

Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. 

Model all 

Potential risks 

Risk of explosion 

In closed air conditioning systems (filled or emptied), high pressure can build up due to heating which can cause the system to burst. For this reason, all welding and soldering work  on or near closed air conditioning systems is prohibited.

Ignitable mixtures may form in combination with refrigerant vapors.

Risk of poisoning 

Refrigerant can break down when overheated. The resulting substances are toxic and should never be inhaled. Avoid contact with skin.

Risk of injury 

Refrigerant vapors are heavier than air; this means that escaping gases pose a risk of suffocation for anyone in a work pit beneath the vehicle.

When the air conditioning system is in operation, high operating temperatures may build up in the high-pressure lines.

Contact with liquid refrigerant may cause frostbite-like damage to the skin (due to undercooling).

Safety instructions/precautions 

First-aid measures