Various fault codes stored in lower control panel control unit (UBF) - AF91.60-P-8701A
MODEL 230
MODIFICATION NOTES
| 11.12.01 | Replaces STIP 82.25-005 dated 10.12.2001 |
OPERATION NO. OF OPERATION TEXTS OR STANDARD TEXTS AND FLAT RATES
| Category | Op. no. | Operation text | Time | Acc. no. | Code |
|---|---|---|---|---|---|
| P | 541011 | PERFORM SHORT TEST | 004 WU/0.3h | - | - |
| Damage code | Cause | Remedy | |
|---|---|---|---|
To enable this, the airbag with integrated emergency call system (ARMIN) control unit connects the discrete line leading to the LCP to ground potential (terminal 31) following terminal 15R ON. |
1 Erase fault memory. | ||
| The LCP then switches on the ACSR lamp. The lamp remains lit until the signal line from the ARMIN is no longer connected to ground potential. | 2 Switch off ignition. |
||
| If terminal 15R quickly changes from ON to OFF and then back to ON, this is not detected by the airbag with integrated emergency call system (ARMIN) control unit and ground potential is therefore not connected to the signal line. | 3 Switch on ignition. |
||
| As a result, fault code B1559 is stored in the LCP. | |||
| The fault code means: The actuation signal from the control unit N2/7 (restraint systems control unit) for the component E16 (automatic child seat recognition airbag OFF indicator lamp) is not received. Automatic child seat recognition |
|||
4 Check signal line from ARMIN control unit. |