Perform measurement of insulation resistance - AR54.10-P-4000SX
Model 221
MODIFICATION NOTES
| 28.9.15 | Screw high-voltage plug to the high-voltage battery | Type 221 | BA54.10-P-1036-01C |
| Risk of death when touching components on vehicles with high-voltage on-board electrical system | Do not touch components and open lines of the high-voltage on-board electrical system. Persons who wear electronic implants (e.g. cardiac pacemakers), must not carry out any work on high-voltage on-board electrical systems. | AS54.00-Z-0001-01A | |
| Evaluation of high-voltage components | AH54.00-P-6500-01SXH | ||
| Note on high-voltage on-board electrical system | AH54.00-P-0010-01A | ||
| Note on high-voltage battery | AH54.10-P-0006-01MEV | ||
| Measure | |||
| 1 | Perform manual power disconnect for high-voltage on-board electrical system | AR54.10-P-1039SX | |
| 2 | Disconnect battery ground cable | AR54.10-P-0003SX | |
| Notes on battery | AH54.10-P-0001-01A | ||
| 3 | Perform insulation resistance measurement at disconnect plug (3) | AR54.10-P-1160-01LF | |
| 000 588 00 19 00 Insulation measuring unit | WS54.00-P-0046B | ||
If the measured value is OK. ↓ Proceed with operation step 5 If the measured value is not OK. ↓ Unplug disconnect plug (3) of high-voltage electrical line (3a) from DC/DC converter control unit. |
Figure | ||
| MODEL 221 | AR54.10-P-1350SXH | ||
| 4 | Perform measurement at disconnect plug (3) again | AR54.10-P-1160-01LF | |
| 000 588 00 19 00 Insulation measuring unit | WS54.00-P-0046B | ||
| If the measured value is OK. ↓ |
|||
| Replace DC/DC converter MODEL 221 If the measured value is not OK. ↓ Replace high-voltage electrical line (3a). |
AR54.10-P-1350SXH | ||
| 5 | Plug test adapter into high-voltage plug connection on high-voltage battery module (A100) | *BA54.10-P-1036-01C | |
| Figure | |||
| 6 | Measure insulation on test adapter | AR54.10-P-1160-01LF | |
| 000 588 00 19 00 Insulation measuring unit | WS54.00-P-0046B | ||
If the measured value is OK. ↓ Proceed with operation step 7 If the measured value is not OK. ↓ |
Figure | ||
| Replace high-voltage battery module (A100) MODEL 221 |
AR54.10-P-1140SXH | ||
| 7 | Perform insulation resistance measurement at high-voltage plug (1) | AR54.10-P-1160-01LF | |
| 000 588 00 19 00 Insulation measuring unit | WS54.00-P-0046B | ||
| If the measured value is OK. ↓ Reassemble vehicle. If the measured value is not OK. ↓ |
|||
| Disconnect electrical connector from electric refrigerant compressor MODEL 221 |
AR83.55-P-5300SXH | ||
| 8 | Perform insulation resistance measurement at high-voltage plug (1) again | AR54.10-P-1160-01LF | |
| 000 588 00 19 00 Insulation measuring unit | WS54.00-P-0046B | ||
| If the measured value is OK. ↓ |
|||
| Replace electric refrigerant compressor. MODEL 221 If the measured value is not OK. ↓ Proceed with operation step 9 |
AR83.55-P-5300SXH | ||
| 9 | Disconnect electrical connectors from electrical machine | MODEL 221 The electrical connectors must be insulated prior to the measurement. Otherwise erroneous measurements will be taken. |
AR08.10-P-0011SXH |
| Figure | |||
| 10 | Perform insulation resistance measurement at high-voltage plug (1) again | AR54.10-P-1160-01LF | |
| 000 588 00 19 00 Insulation measuring unit | WS54.00-P-0046B | ||
| If the measured value is OK. ↓ |
|||
| Replace integrated starter alternator MODEL 221.095/195 If the measured value is not OK. ↓ |
AR15.40-P-0003SXH | ||
| Replace power electronics with power distributor. MODEL 221.095/195 |
AR08.10-P-0011SXH | ||
| 11 | Remove test adapter | Figure | |
| 12 | Reconnect electrical connectors | ||
| 13 | Close any electrical connectors still open with covers | Figure | |
| 14 | Connect ground line to battery | AR54.10-P-0003SX | |
| Notes on battery | AH54.10-P-0001-01A |
BATTERY
| Number | Designation | Model 221 | |
|---|---|---|---|
| BA54.10-P-1036-01C | Screw/bolt, high-voltage connector to high-voltage battery | Nm | 5, 5 |