LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2012 >> S600 >> Repair and Diagnosis >> Electrical >> Body Electrical >> Electrical System, Equipment & Instructions - 221 Chassis - 2 Of 9 >> Testing & Repair >> Check condition of battery >> Check condition of battery - AR54.10-P-1129I

Check condition of battery - AR54.10-P-1129I

MODEL 215, 220, 230 except CODE (P99) Special model "AMG Black Series" 

REMOVING Removing     
DANGER Risk of explosion  caused by escaping oxyhydrogen gas. Risk of injury  caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries  caused by short circuit. Risk of poisoning  caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices No fire, sparks, open flames or smoking. Wear acid-resistant gloves and clothing and safety glasses with side guards.
Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground.
Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers.
AS54.10-Z-0001-01A
NOTES Notes on battery   AH54.10-P-0001-01A
IMPORTANT Notes on AGM battery   AH54.10-P-0002-01A
1 Unhook trunk retractable partition Model 230 to test on-board electrical system battery.  
2 Remove spare tire cover For checking the on-board electrical system battery.  
3 Open engine hood and move to vertical position Model 230 to test starter battery. AR88.40-P-1000R
INSPECT Check     
4 Visually inspect battery for external leaks IMPORTANT If leaks are found, replace battery, see: ↓
Remove/install battery
 
    Model 215, 220 AR54.10-P-0005I
    Model 230 on-board electrical system battery AR54.10-P-0005RA
    Model 230 starter battery AR54.10-P-0005RB
REFER TO FORMS Dispose of battery   OS54.10-P-0001-01Z
5.1 Check fluid level in battery, replenish with distilled water if necessary Without service fill level indicator, not on absorbent glass mat battery.  
5.2 Check fluid level of battery With service fill level indicator, not on absorbent glass mat battery.
IMPORTANT Fluid check via service fill level indicator, acid level is too low if colored white: Replace battery, see: ↓
Remove/install battery
 
    Model 215, 220 AR54.10-P-0005I
    Model 230 on-board electrical system battery AR54.10-P-0005RA
REFER TO FORMS Dispose of battery   OS54.10-P-0001-01Z
6 Check battery   AR54.10-P-1129-01A
Cold cranking amps as per EN  
Battery capacity 12 Ah *BE54.10-P-1001-01A 
Battery capacity 30 Ah *BE54.10-P-1002-01A 
Battery capacity 35 Ah *BE54.10-P-1003-01A 
Battery capacity 46 Ah *BE54.10-P-1005-01A 
Battery capacity 60 Ah VRLA *BE54.10-P-1006-01A 
Battery capacity 60 Ah *BE54.10-P-1007-01A 
Battery capacity 62 Ah *BE54.10-P-1009-01A 
Battery capacity 70 Ah VRLA *BE54.10-P-1010-01A 
Battery capacity 74 Ah *BE54.10-P-1011-01A 
Battery capacity 80 Ah VRLA *BE54.10-P-1012-01A 
Battery capacity 84 Ah *BE54.10-P-1013-01A 
Battery capacity 90 Ah VRLA *BE54.10-P-1014-01A 
Battery capacity 95 Ah VRLA *BE54.10-P-1015-01A 
Battery capacity 100 Ah
Midtronics battery tester
*BE54.10-P-1016-01A 
7 Reduce increased voltage after charging process On a battery that is disconnected from the on-board electrical system and with the message "Surface voltage" in the display of the Midtronics battery tester.
IMPORTANT After reducing increased voltage, test battery again.
Midtronics battery tester
AR54.10-P-1129-03A
8 Charge battery With the test code "Charge and check" on the Midtronics battery tester.
IMPORTANT After charging, test battery again.
Midtronics battery tester
AR54.10-P-1130I
INSTALLING Install     
9 Close engine hood Model 230 after test of starter battery. AR88.40-P-1000R
10 Install spare tire cover After checking the on-board electrical system battery.  
11 Install trunk retractable partition Model 230 after test of on-board electrical system battery.  
TEST AND ADJUSTMENT VALUES FOR BATTERY

Number Designation All models
BE54.10-P-1001-01A Battery capacity 12 Ah Cold test current as per EN A 170
BE54.10-P-1002-01A Battery capacity 30 Ah Battery test at 20°C Acid density kg/dm3 ≥1, 24
Maximum permissible difference between individual battery cells kg/dm3 0, 04
Load current A 90
Load time s 10
Voltage VV ≈10
Cold test current as per EN A 540
BE54.10-P-1003-01A Battery capacity 35 Ah Battery test at 20°C Acid density kg/dm3 ≥1, 24
Maximum permissible difference between individual battery cells kg/dm3 0, 04
Load current A 100
Load time s 10
Voltage VV ≈10
Cold test current as per EN A 520
BE54.10-P-1005-01A Battery capacity 46 Ah Battery test at 20°C Acid density kg/dm3 ≥1, 24
Maximum permissible difference between individual battery cells kg/dm3 0, 04
Load current A 140
Load time s 10
Voltage VV ≈10
Cold test current as per EN A 420
BE54.10-P-1006-01A Battery capacity 60 Ah VRLA Cold test current as per EN A 680
BE54.10-P-1007-01A Battery capacity 60 Ah Cold test current as per EN A 510
BE54.10-P-1009-01A Battery capacity 62 Ah Battery test at 20°C Acid density kg/dm3 ≥1, 24
Maximum permissible difference between individual battery cells kg/dm3 0, 04
Load current A 190
Load time s 10
Voltage VV ≈10
Cold test current as per EN A 480
BE54.10-P-1010-01A Battery capacity 70 Ah VRLA Cold test current as per EN A 760
BE54.10-P-1011-01A Battery capacity 74 Ah Battery test at 20°C Acid density kg/dm3 ≥1, 24
Maximum permissible difference between individual battery cells kg/dm3 0, 04
Load current A 265
Load time s 10
Voltage VV ≈10
Cold test current as per EN A 680
BE54.10-P-1012-01A Battery capacity 80 Ah VRLA Cold test current as per EN A 800
BE54.10-P-1013-01A Battery capacity 84 Ah Cold test current as per EN A 700
BE54.10-P-1014-01A Battery capacity 90 Ah VRLA Cold test current as per EN A 950
BE54.10-P-1015-01A Battery capacity 95 Ah VRLA Cold test current as per EN A 850
BE54.10-P-1016-01A Battery capacity 100 Ah Battery test at 20°C Acid density kg/dm3 ≥1, 24
Maximum permissible difference between individual battery cells kg/dm3 0, 04
Load current A 300
Load time s 10
Voltage VV ≈10
Cold test current as per EN A 760