Check condition of battery - AR54.10-P-1129I
MODEL 215, 220, 230 except CODE (P99) Special model "AMG Black Series"
| Removing | |||
| Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices | No fire, sparks, open flames or smoking. Wear acid-resistant gloves and clothing and safety glasses with side guards. Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground. Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers. |
AS54.10-Z-0001-01A | |
| Notes on battery | AH54.10-P-0001-01A | ||
| Notes on AGM battery | AH54.10-P-0002-01A | ||
| 1 | Unhook trunk retractable partition | Model 230 to test on-board electrical system battery. | |
| 2 | Remove spare tire cover | For checking the on-board electrical system battery. | |
| 3 | Open engine hood and move to vertical position | Model 230 to test starter battery. | AR88.40-P-1000R |
| Check | |||
| 4 | Visually inspect battery for external leaks | Remove/install battery |
|
| Model 215, 220 | AR54.10-P-0005I | ||
| Model 230 on-board electrical system battery | AR54.10-P-0005RA | ||
| Model 230 starter battery | AR54.10-P-0005RB | ||
| Dispose of battery | OS54.10-P-0001-01Z | ||
| 5.1 | Check fluid level in battery, replenish with distilled water if necessary | Without service fill level indicator, not on absorbent glass mat battery. | |
| 5.2 | Check fluid level of battery | With service fill level indicator, not on absorbent glass mat battery. Remove/install battery |
|
| Model 215, 220 | AR54.10-P-0005I | ||
| Model 230 on-board electrical system battery | AR54.10-P-0005RA | ||
| Dispose of battery | OS54.10-P-0001-01Z | ||
| 6 | Check battery | AR54.10-P-1129-01A | |
| Cold cranking amps as per EN | |||
| Battery capacity 12 Ah | *BE54.10-P-1001-01A | ||
| Battery capacity 30 Ah | *BE54.10-P-1002-01A | ||
| Battery capacity 35 Ah | *BE54.10-P-1003-01A | ||
| Battery capacity 46 Ah | *BE54.10-P-1005-01A | ||
| Battery capacity 60 Ah VRLA | *BE54.10-P-1006-01A | ||
| Battery capacity 60 Ah | *BE54.10-P-1007-01A | ||
| Battery capacity 62 Ah | *BE54.10-P-1009-01A | ||
| Battery capacity 70 Ah VRLA | *BE54.10-P-1010-01A | ||
| Battery capacity 74 Ah | *BE54.10-P-1011-01A | ||
| Battery capacity 80 Ah VRLA | *BE54.10-P-1012-01A | ||
| Battery capacity 84 Ah | *BE54.10-P-1013-01A | ||
| Battery capacity 90 Ah VRLA | *BE54.10-P-1014-01A | ||
| Battery capacity 95 Ah VRLA | *BE54.10-P-1015-01A | ||
| Battery capacity 100 Ah Midtronics battery tester |
*BE54.10-P-1016-01A | ||
| 7 | Reduce increased voltage after charging process | On a battery that is disconnected from the on-board electrical system and with the message "Surface voltage" in the display of the Midtronics battery tester. Midtronics battery tester |
AR54.10-P-1129-03A |
| 8 | Charge battery | With the test code "Charge and check" on the Midtronics battery tester. Midtronics battery tester |
AR54.10-P-1130I |
| Install | |||
| 9 | Close engine hood | Model 230 after test of starter battery. | AR88.40-P-1000R |
| 10 | Install spare tire cover | After checking the on-board electrical system battery. | |
| 11 | Install trunk retractable partition | Model 230 after test of on-board electrical system battery. |
TEST AND ADJUSTMENT VALUES FOR BATTERY
| Number | Designation | All models | |||
|---|---|---|---|---|---|
| BE54.10-P-1001-01A | Battery capacity 12 Ah | Cold test current | as per EN | A | 170 |
| BE54.10-P-1002-01A | Battery capacity 30 Ah | Battery test at 20°C | Acid density | kg/dm3 | ≥1, 24 |
| Maximum permissible difference between individual battery cells | kg/dm3 | 0, 04 | |||
| Load current | A | 90 | |||
| Load time | s | 10 | |||
| Voltage | VV | ≈10 | |||
| Cold test current | as per EN | A | 540 | ||
| BE54.10-P-1003-01A | Battery capacity 35 Ah | Battery test at 20°C | Acid density | kg/dm3 | ≥1, 24 |
| Maximum permissible difference between individual battery cells | kg/dm3 | 0, 04 | |||
| Load current | A | 100 | |||
| Load time | s | 10 | |||
| Voltage | VV | ≈10 | |||
| Cold test current | as per EN | A | 520 | ||
| BE54.10-P-1005-01A | Battery capacity 46 Ah | Battery test at 20°C | Acid density | kg/dm3 | ≥1, 24 |
| Maximum permissible difference between individual battery cells | kg/dm3 | 0, 04 | |||
| Load current | A | 140 | |||
| Load time | s | 10 | |||
| Voltage | VV | ≈10 | |||
| Cold test current | as per EN | A | 420 | ||
| BE54.10-P-1006-01A | Battery capacity 60 Ah VRLA | Cold test current | as per EN | A | 680 |
| BE54.10-P-1007-01A | Battery capacity 60 Ah | Cold test current | as per EN | A | 510 |
| BE54.10-P-1009-01A | Battery capacity 62 Ah | Battery test at 20°C | Acid density | kg/dm3 | ≥1, 24 |
| Maximum permissible difference between individual battery cells | kg/dm3 | 0, 04 | |||
| Load current | A | 190 | |||
| Load time | s | 10 | |||
| Voltage | VV | ≈10 | |||
| Cold test current | as per EN | A | 480 | ||
| BE54.10-P-1010-01A | Battery capacity 70 Ah VRLA | Cold test current | as per EN | A | 760 |
| BE54.10-P-1011-01A | Battery capacity 74 Ah | Battery test at 20°C | Acid density | kg/dm3 | ≥1, 24 |
| Maximum permissible difference between individual battery cells | kg/dm3 | 0, 04 | |||
| Load current | A | 265 | |||
| Load time | s | 10 | |||
| Voltage | VV | ≈10 | |||
| Cold test current | as per EN | A | 680 | ||
| BE54.10-P-1012-01A | Battery capacity 80 Ah VRLA | Cold test current | as per EN | A | 800 |
| BE54.10-P-1013-01A | Battery capacity 84 Ah | Cold test current | as per EN | A | 700 |
| BE54.10-P-1014-01A | Battery capacity 90 Ah VRLA | Cold test current | as per EN | A | 950 |
| BE54.10-P-1015-01A | Battery capacity 95 Ah VRLA | Cold test current | as per EN | A | 850 |
| BE54.10-P-1016-01A | Battery capacity 100 Ah | Battery test at 20°C | Acid density | kg/dm3 | ≥1, 24 |
| Maximum permissible difference between individual battery cells | kg/dm3 | 0, 04 | |||
| Load current | A | 300 | |||
| Load time | s | 10 | |||
| Voltage | VV | ≈10 | |||