Check condition of battery - AR54.10-P-1129SY
MODEL 216.3 as of 2.6.08
MODEL 216.3 with CODE (809) Model year 2009
MODEL 221.0/1 as of 2.6.08
MODEL 221.0/1 with CODE (809) Model year 2009
Shown on model 221
Model 221.1 as of 2.6.08 with code (Z07) Top protection
| Removing | |||
| Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices | No fire, sparks, open flames or smoking. Wear acid-resistant gloves and clothing and safety glasses with side guards. Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground. Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers. |
AS54.10-Z-0001-01A | |
| Notes on battery | AH54.10-P-0001-01A | ||
| Notes on AGM battery | AH54.10-P-0002-01A | ||
| 1 | Remove center paneling in trunk or implement carrier plate | Model 221.1 with code (Z07) Top protection and model 221.095/195 | |
| Model 221.1 with code (Z07) Top protection Used to test starter battery (G1/4) | AR68.30-P-4600SXS | ||
| Model 221.095/195 for checking the on-board electrical system battery (G1) |
AR68.30-P-4600SX | ||
| Checking | |||
| 2 | Inspect on-board electrical system battery (G1) for external leakage | ||
| Except model 221.095/195 | AR54.10-P-0009SY | ||
| Model 221.095/195 | AR54.10-P-0009SXH | ||
| 3 | Inspect starter battery (G1/4) for external leakage | Model 221.1 with code (Z07) Top protection |
|
| Remove/install starter battery (G1/4). | AR54.10-P-0008SXS | ||
| 4 | Test on-board electrical system battery (G1) and/or starter battery (G1/4) | AR54.10-P-1129-01A | |
| Cold test current | |||
| Battery capacity 35 Ah | *BE54.10-P-1003-01A | ||
| Battery capacity 60 Ah VRLA | *BE54.10-P-1006-01A | ||
| Battery capacity 70 Ah VRLA | *BE54.10-P-1010-01A | ||
| Battery capacity 80 Ah VRLA | *BE54.10-P-1012-01A | ||
| Battery capacity 90 Ah VRLA | *BE54.10-P-1014-01A | ||
| Battery capacity 95 Ah VRLA | *BE54.10-P-1015-01A | ||
| Battery capacity 100 Ah Battery test/test equipment |
*BE54.10-P-1016-01A | ||
| 5 | Reduce increased voltage after charging process using volt-amp(s) tester | On starter battery (G1/4) or on-board electrical system battery (G1) that is disconnected from the on-board electrical system and where the message "Surface voltage" appears in the display of the Midtronics battery tester. Battery tester |
AR54.10-P-1129-03A |
| 6 | Charge starter battery (G1/4) and/or on-board electrical system battery (G1) | With the test code "Charge and check" on the Midtronics battery tester. |
AR54.10-P-1130SY |
| Install | |||
| 7 | Remove center paneling in trunk or implement carrier plate | Model 221.1 with code (Z07) Top protection and model 221.095/195 | |
| Model 221.1 with code (Z07) Top protection Used to test starter battery (G1/4) | AR68.30-P-4600SXS | ||
| Model 221.095/195 for checking the on-board electrical system battery (G1) |
AR68.30-P-4600SX |
TEST AND ADJUSTMENT VALUES FOR BATTERY
| Number | Designation | All models | |||
|---|---|---|---|---|---|
| BE54.10-P-1003-01A | Battery capacity 35 Ah | Battery test at 20°C | Acid density | kg/dm3 | ≥1, 24 |
| Maximum permissible difference between individual battery cells | kg/dm3 | 0, 04 | |||
| Load current | A | 100 | |||
| Load time | s | 10 | |||
| Voltage | VV | ≈10 | |||
| Cold test current | as per EN | A | 520 | ||
| BE54.10-P-1006-01A | Battery capacity 60 Ah VRLA | Cold test current | as per EN | A | 680 |
| BE54.10-P-1010-01A | Battery capacity 70 Ah VRLA | Cold test current | as per EN | A | 760 |
| BE54.10-P-1012-01A | Battery capacity 80 Ah VRLA | Cold test current | as per EN | A | 800 |
| BE54.10-P-1014-01A | Battery capacity 90 Ah VRLA | Cold test current | as per EN | A | 950 |
| BE54.10-P-1015-01A | Battery capacity 95 Ah VRLA | Cold test current | as per EN | A | 850 |
| BE54.10-P-1016-01A | Battery capacity 100 Ah | Battery test at 20°C | Acid density | kg/dm3 | ≥1, 24 |
| Maximum permissible difference between individual battery cells | kg/dm3 | 0, 04 | |||
| Load current | A | 300 | |||
| Load time | s | 10 | |||
| Voltage | VV | ≈10 | |||
| Cold test current | as per EN | A | 760 | ||