Home >> Mercedes Benz >> 2012 >> ML63 >> Repair and Diagnosis >> External Pages >> Different car >> Section 345 (Seats, Bunks, Restraint Systems - 166 Chassis - 1 Of 3) >> Safety Precautions >> Risk Of Injury During Testing And Repair Operations Related To Pyrotechnical Components - AS91.00-Z-0008-01A

Risk Of Injury During Testing And Repair Operations Related To Pyrotechnical Components - AS91.00-Z-0008-01A

WARNING: This page does not describe the selected car, but rather 27 other vehicles, including the 2019 Mercedes-Benz GLE63 S AMG, 2019 Mercedes-Benz GLE63 AMG, 2019 Mercedes-Benz GLE43 AMG, 2019 Mercedes-Benz GLE400, and 2018 Mercedes-Benz GLE63 S AMG. However, it is still accessible from the selected car via links, so may be relevant.

MODEL ALL (4xWD, CAR, Heavy transporter, Light transporter, TRUCK, smart) 

Do not expose pyrotechnical components to temperatures above 100 °C Or 212 °F. Disconnect Current Supply When Working On Such Components.

  Information, assessment and legal requirements when working with, handling and storing pyrotechnical components   AH91.00-Z-0000-10A 

Risk of injury and burn injuries 

Risk of injury from flying components and loud noise, strong smoke and heat emissions in the case of uncontrolled ignition of pyrotechnical components. Risk of burn injuries if ignited pyrotechnical components that are still hot are touched.

Rules of conduct and safety precautions for handling pyrotechnical components 

First aid measures in case of burns