LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2012 >> GLK350 Base >> Repair and Diagnosis >> Electrical >> Motors, Switches, Relays >> Electrical System - Body - 204 Chassis - 1 Of 6 >> Basic Knowledge >> Overhead control panel electronics, component description - GF82.20-P-5217CE

Overhead control panel electronics, component description - GF82.20-P-5217CE

MODEL 204 except CODE (414) Power glass tilting/sliding roof as of model year 2009/YoM 08 

Fig 1: Identifying Control Panel Control Electronics Components
G10084716Courtesy of MERCEDES-BENZ USA

With code (359) TELEAID emergency call system or code (348) Emergency call/Assist system 

Fig 2: Identifying Control Panel Control Electronics Components
G10084717Courtesy of MERCEDES-BENZ USA

Location 

The overhead control panel electronics is located at the front on the headliner.

Task 

The controls of the following systems are located on the overhead control panel electronics.

The node of the wiper/inside rearview mirror-LIN (LIN 2) is integrated into the overhead control panel electronics. The following components are connected to the node:

The overhead control panel electronics are supplied with voltage by the front SAM control unit.

The following components are supplied with voltage by the overhead control panel electronics:

The housing of the overhead control panel electronics also contains the following components:

In vehicles with code (359) TELEAID emergency call system or code (348) Emergency call/Assist system the emergency call system control unit (N123/4) directly reads in the control signal for the buttons (emergency call system, MB Info, breakdown assistance) and evaluates them.

The LEDs (function, status feedback) integrated into the buttons (emergency call system, MB Info, breakdown assistance) are actuated by the emergency call system control unit.

The buttons (emergency call system, MB Info, breakdown assistance) are all equipped with a contact resistor (connected in parallel to switch contact). In the rest position these have a voltage applied to them. The voltage difference between the input and output side of the contact resistor is used by the emergency call system control unit to check the feed lines and ground lines.

When a button (emergency call system, MB Info, breakdown assistance) is pressed, each contact resistor is bridged by the respective switch contact. The control signals for the buttons (emergency call system, MB Info, breakdown assistance) are read in by the emergency call system control unit over 2 direct lines. When a button (emergency call system, MB Info, breakdown assistance) is operated, the emergency call system control unit implements the respective request and then actuates each LED intermittently (visual feedback). In the event of a fault in the emergency call system both red LEDs are permanently actuated.

REFER TO SYSTEM WIRING DIAGRAMS Wiring diagram for overhead control panel (OCP) control unit   PE54.21-P-2107-97FAB