Remove/install on-board electrical network line pyrofuse in vehicle power supply control unit - AR54.15-P-1262GZ
MODEL 164.822
| Remove/install | |||
| Information on preventing damage to electronic components due to electrostatic discharge | AH54.00-P-0001-01A | ||
| Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices | No fire, sparks, open flames or smoking. Wear acid-resistant gloves and clothing and safety glasses with side guards. Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground. Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers. |
AS54.10-Z-0001-01A | |
| 1 | Disconnect battery ground line | AR54.10-P-0003GZ | |
| 2 | Remove front floor covering | AR68.20-P-2070GZ | |
| 3 | Unscrew nuts (1). | ||
| 4 | Remove bolt (2) | ||
| 5 | Remove intermediate bottom (3) | ||
| 6 | Remove molded part (4) | ||
| 7 | Detach adhesive tape (5) | ||
| 8 | Disconnect electrical connector (6) | ||
| 9 | Unscrew nuts (7) | *BA54.15-P-1002-01D | |
| 10 | Remove lines (8) | ||
| 11 | Remove pyrotechnical separating element (K88) | ||
| 12 | Install in the reverse order |
FUSE BOX
| Number | Designation | Model 164.822 | |
|---|---|---|---|
| BA54.15-P-1002-01D | Nut, pyrofuse to vehicle power supply control unit | Nm | 18 |