Regulation of Automatic air conditioning, function - GF83.40-P-2004G

MODEL 463.306 /336 /346 as of model year 2011 /YoM 10 

MODEL 463.202 /222 /236 /237 as of model year 2009 /YoM 08 

MODEL 463.247 /248 /249 /254 /270 /271 /303 /340 /341 as of model year 2007 

Fig 1: Regulation Of Automatic Air Conditioning Function Diagram
G07740596Courtesy of MERCEDES-BENZ USA

Automatic air conditioning (without code (HH7) Additional air conditioning in rear) 

Function requirements 

IMPORTANT The status of circuit 15 is sent by the EZS control unit via interior CAN (CAN B).

The status of circuit 61 is sent by the CDI control unit or by the ME-SFI [ME] control unit via drive train CAN (CAN C) to the EZS control unit. It routes the message to the interior CAN. The control and operating unit receives the respective message.

General function sequence regulation 

The electronic regulation of the temperature and the air distribution in the interior takes place depending on the settings selected on the control and operating unit and the basic conditions detected by the various sensors (e.g. interior temperature, outside temperature, coolant temperature).

The determination of these variables is described following the description of the adjustments that are relevant for regulation.

The control and operating unit is networked via interior CAN and A/C bus with the vehicle electronics system. This in turn makes it possible to incorporate relevant parameters in order to improve regulation quality and to lower power consumption.

Adjustments that are relevant for regulation 

Automatic regulation 

Additional function requirements 

Function sequence for automatic regulation 

The temperature, air distribution and air volume are regulated depending on the temperature preselection at the control and operating unit and the ambient parameters listed below.

The air is cooled down through regulated actuation of the refrigerant compressor. Heating takes place by admixing air heated by the heater heat exchanger through the blend air flaps.

The blower motor is actuated by the control and operating unit via the blower regulator.

Actuation takes place via the following components:

Manual regulation 

Additional function requirements 

Function sequence with manual regulation 

The regulation of temperature, air distribution, and air volume takes place depending on the adjustments made on the control and operating unit.

Recirculated air function 

Additional function requirements 

Function sequence of the recirculated air function 

By activating the function, the fresh air/air recirculation flaps are closed and the air circulates in the vehicle interior.

The time of the recirculated air function is limited in the following cases:

Defrost function 

Additional function requirements 

Function sequence of defroster function 

By activating the function, the previously made adjustments are superimposed.

The defroster flaps are adjusted by the left and right defroster flaps actuator motor so that the maximum air flow is directed to the windshield and the front side windows.

Refrigerant compressor switched on or off 

By pressing the A/C button, the actuation of the refrigerant compressor is deactivated. The other functions of the automatic air conditioning continue being available. However, a cool-down below the current outside temperature is not possible.

Determination of the variables for regulating the automatic air conditioning: 

Rear air conditioning (with code (HH7) Additional air conditioning in rear) 

Fig 2: Regulation Of Automatic Air Conditioning Function Diagram - With Code (HH7) Additional Air Conditioning In Rear
G07740597Courtesy of MERCEDES-BENZ USA

Function sequence for regulation of rear air conditioning (with code (HH7) Additional air conditioning in rear) 

The rear air conditioning cools the interior air to the temperature level preselected by the rear passengers. The system works depending on the settings selected by the rear passengers as well as the evaporator temperature. The delivered ambient air is cooled and dehumidified in the evaporator here. The air is distributed in the interior via the mixed air vents of the rear air conditioner housing. The temperature of the emitted cold air is monitored by the rear air conditioning evaporator temperature sensor here and shown graphically on the display of the rear air conditioning control unit.

The rear air conditioning control unit receives the circuit status as well as the status of the refrigerant compressor via interior CAN from the AAC [KLA] control and operating unit.

The air distribution is performed via the top and bottom air distribution actuator motor depending on the selected setting.

IMPORTANT The rear air conditioner only enables cooling of the ambient air; a temperature increase as well as automatic regulation of the temperature level is not possible.

  Heating system heat exchanger, component description   GF83.20-P-3123G 
  Component description for instrument cluster A1
Model year 07.5, modification year 07
GF54.30-P-6000G
  Component description of refrigerant compressor A9 GF83.55-P-2108G
  Blower, component description A32m1, A32n1 GF83.10-P-2050G 
  Evaporator temperature sensor, component description B10/6 GF83.57-P-2126G
  Coolant temperature sensor, component description B11/4 GF07.04-P-6040G
  Refrigerant pressure and temperature sensor, component description B12/2 GF83.40-P-2195G 
  Component description for the outside temperature indicator temperature sensor B14 GF83.57-P-4002G
  Component description of air humidity sensor B31/2 GF83.30-P-2130G 
  Automatic air conditioning actuator motors, component description M2/5, M2/6, M2/7, M2/15, M2/16 and M2/21 GF83.40-P-2197G 
  Additional fan, component description M4 GF83.40-P-4010G 
  Coolant circulation pump component description M13 GF83.75-P-2110G
  Component description for front SAM control unit with fuse and relay module N10/1 GF54.21-P-6070G
  Component description for rear SAM control unit with fuse and relay module N10/2 GF54.21-P-6030G
  Component description for automatic air conditioning control and operating unit N22 GF83.40-P-3000G 
  Component description for left front door control unit N69/1 GF72.29-P-4141G
  Component description for right front door control unit N69/2 GF72.29-P-4142G
  Rear door control unit, component description N69/3, N69/4
Model 463.236/237/248/249/270/271/341/346