Initial operation of new tandem pump - AR32.50-P-0021-01N
Shown on model 220
Air is bled from a new tandem pump when the ABC system is pressurized.
- Connect suitable pressure hose (084a)
to pressure pump (084).
- Pull dipstick out of the expansion reservoir (2).
- Insert the pressure hose (084a) into the fitting of the dipstick opening and press on firmly.
2nd person required.
- Use
pressure pump (084) to produce a pressure of approx. 1 bar.
- Start engine.