LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2012 >> CL65 >> Repair and Diagnosis >> Electrical >> Motors, Switches, Relays >> Electrical System -- Testing & Repair -- Cl65 AMG (216.379) >> Testing & Repair >> Disconnect and disconnect ground line from on-board electrical system with one battery - AR54.10-P-0003-02SXS - 2 of 2

Disconnect and disconnect ground line from on-board electrical system with one battery - AR54.10-P-0003-02SXS - 2 of 2

DANGER Risk of explosion  caused by oxyhydrogen gas. Risk of poisoning and caustic burns  caused by swallowing battery acid. Risk of injury  caused by burns to skin and eyes from battery acid or when handling damaged lead-acid batteries No fire, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers. AS54.10-Z-0001-01A
NOTES Notes on battery   AH54.10-P-0001-01A
Fig 1: Identifying Ground Line And Negative Terminal Of On-Board Electrical System Battery (Shown On Model 221)
G07516750Courtesy of MERCEDES-BENZ USA

Shown on model 221 

  1. Loosen nut on ground line (1) and remove ground line (1) from negative terminal of on-board electrical system battery (G1).

    NOTESInstallation:  Ensure that the ground line (1) is seated tightly, otherwise the electrical system may be damaged.

  2. Using a diode test lamp, check the electrical system for voltage between the positive line of the on-board electrical system battery (G1) and the disconnected ground line (1).

    NOTES If the diode test lamp lights up, the on-board electrical system is still active because of a defect in the electrical system.

    In this case the ground line of the additional battery should be disconnected.

    After this the electrical system is to be repaired upon completion of the work carried out.

  3. Connect in reverse order.