Measures for preventing damage to components when performing electric welding and soldering work - AH60.00-P-0001-02A
All models
In order to prevent damage to vehicle components, the following measures must be taken before welding/soldering:
- Disconnect ignition key and disconnect/insulate ground line from battery.
- When performing electrical welding and soldering work in the area of the airbag control unit (distance < 0.5 m), disconnect electrical connector from airbag control unit.
- The high-voltage battery, the gas tank and the gas-routing components should not exceed a temperature of > 60°C.
- Before welding and soldering, cover all components to protect against flying sparks and radiant heat or remove from hazardous area (including lines and components in hollow cavities).
- Do not touch electronics housings or electrical lines with welding electrode or ground line from the welder/solder.
- Directly connect ground terminal from electrical welding and soldering unit to component to be welded/soldered. Ensure that there are no electrically insulating parts between the ground terminal and the welding/soldering point.
- Do not connect ground terminal from electrical welding/soldering unit to major assemblies (e.g. transmission, engine, etc.).