Notes on crimping - AH00.19-P-1000-09A

MODEL ALL 

1 Check crimped connections for correct forming and filling (cross-section, ensure leads are enclosed correctly).

IMPORTANTCorrect crimped connection (A): 

The strands of the cable are evenly enclosed.

The crimp tab is evenly shaped.

IMPORTANTIncorrect crimped connection (B): 

The crimp tab has an incorrect cross-section and is not full enough.

IMPORTANTIncorrect crimped connection (C): 

Individual wire strands are outside the crimp shackle.

The crimp tab is too full.

IMPORTANTIncorrect crimped connection (D): 

The crimp claws touch the bottom of the crimped fitting.

The crimp tab is too full.

The crimp tab is deformed and therefore damaged.

Shown with circular conductor 

Fig 1: Identifying Crimped Connections For Correct Forming And Filling
G10035758Courtesy of MERCEDES-BENZ USA

2a Check crimped connection without single-strand insulation (ensure line is enclosed correctly).

IMPORTANTCorrect crimped connection (A): 

Leads (3) enclosed correctly by the tab (2).

Insulation is enclosed correctly by the tab (1).

IMPORTANTIncorrect crimped connection (B, C): 

Leads (3) are damaged due to deformed tab (2).

Insulation is pinched by deformed tab (1) and damaged.

Fig 2: Identifying Crimped Connection Without Single-Strand Insulation
G10035759Courtesy of MERCEDES-BENZ USA

2b Check crimped connection with single-strand insulation (ensure line is enclosed correctly).

IMPORTANT Insulation and single-strand insulation must be positioned in the center and enclosed completely by the crimp tab and they must be able to take up tensile force.

NOTES Single strand insulation must not be pinched, as otherwise water ingress can cause contact corrosion.

IMPORTANTCorrect crimped connection (A): 

Wire strands are enclosed correctly by the shackle. Insulation and single-strand insulation are enclosed correctly by the large shackle. All parts can withstand the required tensile force.

IMPORTANTIncorrect crimped connections (B, C): 

The single-strand insulation is not enclosed by the shackle because it was inserted incorrectly during the crimping procedure.

The crimped area of the single-strand insulation is damaged because the wrong die set or wrong single-strand insulation was used.

Fig 3: Identifying Crimped Connection With Single-Strand Insulation
G10035760Courtesy of MERCEDES-BENZ USA

3a Check crimped connection without single-strand insulation (ensure leads and insulation are of correct length).

IMPORTANTCorrect crimped connection (A): 

Correct length of insulation is enclosed by the shackle (1).

Wires (3) are the correct length in the tab (2).

IMPORTANTIncorrect crimped connection (B): 

Insulation is too short and is not correctly enclosed by the tab (1).

Therefore insulation cannot withstand the required tensile load.

IMPORTANTIncorrect crimped connection (C, D): 

Wire strands (3) are too long.

Leads (3) are too short.

Fig 4: Locating Crimped Connection Without Single-Strand Insulation
G10035761Courtesy of MERCEDES-BENZ USA

3b Check crimped connection with single-strand insulation (check for correct length and distance of leads and insulation, as well as position and condition of seal).

IMPORTANTCorrect crimped connection (A): 

Insulation and wires are of the correct length in the shackles. Correct distance between the single-strand insulation and the end of the insulation.

IMPORTANTIncorrect crimped connections (B, C): 

The single-strand insulation is damaged because the distance between seal and end of insulation is too small.

Stripped strands are too long, single-strand insulation is therefore not crimped.

Fig 5: Locating Crimped Connection With Single-Strand Insulation
G10035762Courtesy of MERCEDES-BENZ USA