Remove / install actuator motor for left and right footwell flaps - AR83.10-P-2008V
MODELS 171.4
Fig 1: Identifying Left And Right Footwell Flaps Positioning Motor, Heater/AC Housing And Electrical Connector
| Removal/installation | |||
|---|---|---|---|
| 1 | Remove cover below instrument panel on left | AR68.10-P-1500V | |
| 2 | Disconnect electrical connector (1). | ||
| 3 | Unscrew bolts (2) | ||
| 4 | Remove left and right footwell flaps actuator motor (M2/15) from the heater, AC housing (3) | ||
| 5 | Install in the reverse order | ||
| 6 | Synchronize the actuator motors | ||
| Connect STAR DIAGNOSIS, read out fault memory | AD00.00-P-2000-04A | ||
| Diagnosis system STAR DIAGNOSIS | *WH58.30-Z-1048-13A |
COMMERCIALLY AVAILABLE TOOLS
| Number | Designation | |
|---|---|---|
| WH58.30-Z-1048-13A | STAR DIAGNOSIS diagnosis system, Compact Passenger Car | 6511 1801 00 |