Information on application of sealant to timing case cover - AH01.40-P-1000-01C
Engine 137.970, 275
Application of sealant to timing case cover
The line (F
) marks the application of the sealing compound.
The sealant must be applied only to the specified surfaces with a bead of 2.0 mm 0.5 mm.
The sealing compound must be applied within 10 minutes
The sealing compound bead must not be spread. Only the approved sealing compound must be used.