Home >> Mercedes Benz >> 2011 >> ML450 >> Repair and Diagnosis >> Body & Frame >> Door Locks >> Central Locking System - 164 Ml Class - 2 Of 2 >> Wiring Diagrams >> Legend of electrical function diagram for antitheft alarm system activation - PE80.50-U-2052-60MAA

Legend of electrical function diagram for antitheft alarm system activation - PE80.50-U-2052-60MAA

MODEL 164 as of Model Year 09 with CODE (551) Anti-theft alarm system (ATA [EDW]) 

Item Designation Coordinates
A1 Instrument cluster 10A
A2/93 Roof antenna module 8D
A8/1 Transmitter key 5B
A8/1 Transmitter key 5F
A26/1 Left front IR receiver 2D
A72 Rear door locking unit 7G
M14/5s1 Right front door rotary tumbler microswitch 13H
M14/6s1 Left front door rotary tumbler microswitch 13H
M14/8s1 Left rear door rotary tumbler microswitch 13H
M14/9s1 Right rear door rotary tumbler microswitch 13J
N10/8 Rear SAM control module 10E
N69/1 Left front door control module 2E
N70 Overhead control panel control module 10J
N72/1 Upper control panel control module 14F
N72/1e2 ATA [EDW] function indicator 14D
N73 EIS [EZS] control unit 5E
S62 ATA [EDW] hood switch 8H
CAN B Interior CAN 7F
CAN B Interior CAN 10D
CAN B Interior CAN 10G
CAN B Interior CAN 12F
1 Access authorization code, signal 2C
1 Access authorization code, signal 2E
1 Access authorization code, signal 4F
1 Access authorization code, signal 6F
1 Access authorization code, signal 8C
1 Access authorization code, signal 9E
2 Lock/unlock central locking, request 2E
2 Lock/unlock central locking, request 3B
2 Lock/unlock central locking, request 3F
2 Lock/unlock central locking, request 6F
2 Lock/unlock central locking, request 7C
2 Lock/unlock central locking, request 9D
3 Central locking (CL[ZV]), status 8F
4 Rear-end door locking unit, status 8G
5 Door rotary tumbler switch, status 11G
6 Interior protection deactivated, signal 10D
7 Tow-away protection deactivated, signal 10D
8 ATA [EDW] activated, signal 13F
9 ATA [EDW] engine hood switch, status 9G
10 ATA [EDW] function indicator, actuation 15D
11 Activate interior protection, request 10H