Legend of electrical function schematic for breakdown assistance, function - PE82.95-P-2068-60MAA
Model 164.1 with CODE (359) TELE AID emergency call system as of Model Year 09/YoM 08 model refinement package
Model 164.8 with CODE (359) TELE AID emergency call system as of Model Year 09/YoM 08
| Code | Designation | Coordinates |
|---|---|---|
| A1 | Instrument cluster | 6B |
| A2/50 | TELE AID spare antenna | 2C |
| A2/93a4 | TELE AID antenna | 4H |
| A40/3 | COMAND operating, display and controller unit | 6J |
| N93 | Central gateway control unit | 6E |
| N123/4 | Emergency call system control unit | 2E |
| S93/6s2 | Telediagnosis button | 2J |
| CAN B | Interior CAN | 6D |
| CAN B | Interior CAN | 6G |
| CAN-D | Diagnostic CAN | 4F |
| 1 | VCS ON button, signal | 3G |
| 2 | Telephone, signal | 2D |
| 2 | Telephone, signal | 4G |
| 3 | Status indication, signal | 2J |
| 3 | Status indication, signal | 5E |
| 3 | Status indication, signal | 7D |
| 3 | Status indication, signal | 7H |
| 4 | Audio unit display, message | 5E |
| 4 | Audio unit display, message | 7H |